WPR300-0-0-AC-04
March 2009
Page 13
Single Key 8-bit Burst Mode
To select this mode, specify the Fixed Length Buffered Mode to be “018”. This mode
reports each single key press as 8-bit code. Use Single Key 8-bit Burst Mode when
using Wiegand Readers in PAC Mode or TAG+PIN Mode.
Key
Output
0
11110000
1
11100001
2
11010010
3
11000011
4
10110100
5
10100101
6
10010110
7
10000111
8
01111000
9
01101001
*
01011010
#
01001011
Doorbell (WKM900 only)
00111100
Table 2: Single Key 8-bit Burst Mode
Setting Single Key 8-bit Burst Mode
1.
Press and hold down key '2' until the Reader beeps continuously.
2.
Enter „018‟ and finish by pressing the Hash Key (#).
3.
On acceptance of the change, the Status LED will change to Green.
4.
If the change is rejected the Status LED will change to Red.
Entering a Facility Code
A Facility Code only applies when PIN-codes are used. It is reported as part of the
Wiegand code and can be used to link a set of Wiegand Readers to a particular Site.
A Facility Code can be entered into the Reader's memory. To set the Facility Code, do
the following:
1.
Press and hold down key '1' for 3 seconds. The Status LED will enter a fast flash
Amber Mode.
2.
Enter the Facility Code in the range 0 to 255 and finish by pressing the Hash Key
(#).
3.
On acceptance of the Facility Code the Status LED will briefly change to Green
and the Buzzer will sound.
4.
If the Facility Code is rejected the Status LED will change to Red for a longer
period and the Buzzer will sound.