![background image](http://html1.mh-extra.com/html/amano/pioneer-eclipse-250ap115/pioneer-eclipse-250ap115_operators-manual_2918108005.webp)
5
EN
Electrical Connection Instructions (120V)
This appliance is for use on a nominal 120-volt circuit,
and has a grounding plug that looks like the plug
illustrated in sketch A.
*This applies only
to North America.
Most other countries
use 230V circuit.
WARNING:
UV-C emitted from this product. Avoid
eye and skin exposure to unshielded product. Follow
installation instructions and user manual.
WARNING:
Do not operate device without filter and
cover securely attached. Operating in this manner could
expose those nearby to UV-C radiation UV-C radiation
can cause severe burns of the skin and eye injuries,
(photokeratitis).
GROUNDING
PIN
GROUNDING
OUTLET
GROUNDED
OUTLET BOX
Description
250AP115
250AP115C
250AP230
Voltage (V)
115
115
230
Current (A)
3.5
3.5
1.8
Power (W)
403
403
414
AIR FLOW
High Speed
2700 CFM
2700 CFM
2700 CFM
4587 CMH
4587 CMH
4587 CMH
Low Speed
1785 CFM
1785 CFM
1785 CFM
3033 CMH
3033 CMH
3033 CMH
Weight
57 lbs (25,9 kg)
57 lbs (25,9 kg)
55 lbs (24,9 kg)
Length
24” (61 cm)
24” (61 cm)
24” (61 cm)
Width
22.5” (57 cm)
22.5” (57 cm)
22.5” (57 cm)
Height
34” (86 cm)
34” (86 cm)
34” (86 cm)
SOUND LEVEL
High Speed
68.9 dBa
68.9 dBa
68.9 dBA
Low Speed
61.9 dBa
61.9 dBa
61.9 dBA
Cord
20 ft x 16/3 SJTW
20 ft x 16/3 SJTW
60 cm x 3,3 mm
2
| C20 Connection
Fan Blade
6 x 16.5” (42 cm)
6 x 16.5” (42 cm)
6 x 16.5” (42 cm)
Circuit Breaker
12 Amp
12 Amp
5 Amp
GFCI
Yes
Yes
No
Technical Specifications
receptacle shown in figure 5. The green and yellow
conductor cord is the ground wire. Never connect this
wire to any terminal other than the ground terminal.
WARNING:
Always use this machine with an AC three
conductor electrical system connected to the electrical
ground. Replace any worn, cut, or damaged cords.
Replace any damaged plugs, receptacles, or connector
bodies. Do not move the machine over an electrical
cord. Always lift the cord over the machine.
CAUTION:
This machine will operate only on the AC
frequency and electrical voltage shown on the nameplate.
Make sure you have the correct frequency and voltage
before connecting the power cord to an outlet.
This machine must be connected to the electrical ground
to protect the operator from electric shock. The machine
has a power cord with two main conductors and one
earthing conductor. Connect the plug to the type of
Electrical Connection Instructions (230V)