background image

 

MDR300-0-0-AC-02 

September 2010 

Page 3 

 

INSTALLATION INFORMATION 

Accessories 

Find the following when unpacking the Multi-discipline Reader: 

 

Either an Amano (MDR) Multi-discipline Reader (MDR900-5-0-AC-XX) housed in a 
Polycarbonate and 304 Stainless Steel housing.  The Multi-discipline Reader 
consists of a Front Cover and a Backing Plate.  The Backing Plate is attached with 
4 clips.  

 

Or an Amano (MDK) Multi-discipline Keypad Reader (MDK900-5-0-AC-XX) housed 
in a Polycarbonate and 304 Stainless Steel housing.  The Multi-discipline Reader 
consists of a Front Cover and a Backing Plate.  The Backing Plate is attached with 
4 clips. 

 

One 2-Way Programming Pin. 

 

A Front Cover Removal Tool. 

 

An extra Serial Number Label. 

General 

Remember the following when installing the Multi-discipline Readers: 

Maximum Data Communications Distance 

Install the Multi-discipline Readers no further than 150 m (164 yd) from the Host unit.  
The cable individual conductor cross-sectional area should not be less than 0.2 mm

2

 

(0.0003 in

2

).   

Distance between Multi-discipline Readers 

To avoid mutual interference, install the Multi-discipline Readers no closer than        
500 mm (20 in) apart. 

Mounting the Multi-discipline Readers 

CAUTION: 

Do NOT attach the Front Cover to the Backing Plate prior to 
mounting.   

CAUTION: 

Ensure that you set the Multi-

discipline Reader’s Output Mode 

BEFORE attaching the Front Cover to the Backing Plate.  See page 
for more information. 

CAUTION: 

Make certain that you mount the Readers on a vibration-free 
surface. 

Select the mounting position of the Multi-discipline Readers, considering accessibility, 
routing of wires and visibility of the externally visible LED. 

Secure the Multi-discipline Readers to the mounting surface, using four suitable screws 
and wall plugs, nuts and bolts or rivets.   

 

 

 

Blank Space 

 

 

Summary of Contents for MDK900-5-0-AC Series

Page 1: ...similar to IP54 The Multi discipline Readers are therefore sealed potted against water Input Voltage Rating 8 V DC to 14 V DC polarity sensitive Power Requirements Current mA Power W Supply Voltage 1...

Page 2: ...onnect the Purple and Gray wires to a Dry Contact Input On Amano Systems it is unnecessary to connect these lines as the Software handles the Anti tamper MDK900 model only Keypad 12 Alphanumeric keys...

Page 3: ...Communications Distance Install the Multi discipline Readers no further than 150 m 164 yd from the Host unit The cable individual conductor cross sectional area should not be less than 0 2 mm 2 0 000...

Page 4: ...tember 2010 Page 4 ELECTRICAL CONNECTIONS Connecting the Multi discipline Reader Figure 1 to Figure 5 show typical connections for the Multi discipline Reader Figure 1 Multi discipline Reader Connecte...

Page 5: ...MDR300 0 0 AC 02 September 2010 Page 5 Figure 2 Multi discipline Reader Connected to the Nexus 220 Controller...

Page 6: ...MDR300 0 0 AC 02 September 2010 Page 6 Figure 3 Multi discipline Reader Connected to the Amano MfT...

Page 7: ...MDR300 0 0 AC 02 September 2010 Page 7 Figure 4 Multi discipline Reader Connected to the Amano TA or Amano iTA...

Page 8: ...MDR300 0 0 AC 02 September 2010 Page 8 Figure 5 Multi discipline Reader Connected to the Amano RL Amano RS and Amano RH...

Page 9: ...M Use Only The Multi discipline Readers offer four different Output Mode Combinations Select the Output Mode by doing the following 1 On the back of the Multi discipline Reader locate and bridge the t...

Page 10: ...utton Keypad is used to enter 5 digit PIN codes in the range 00000 to 65535 Wiegand protocol constraints disallow PIN codes from 65536 to 99999 In this case the Status LED turns Red and the Buzzer act...

Page 11: ...is entered for the key buffer length then the Key Mode reverts to PIN Mode 3 On acceptance of the setting the Status LED changes to Green 4 If the settings are rejected the Status LED changes to Red...

Page 12: ...beep for 2 seconds When the Multi discipline Reader passes the Self test it emits two short beeps each 200 ms in duration separated by a 200 ms inter beep pause When the Multi discipline Reader is co...

Page 13: ...MDR300 0 0 AC 02 September 2010 Page 13 USER NOTES...

Page 14: ...MDR300 0 0 AC 02 September 2010 Page 14 USER NOTES...

Page 15: ...MDR300 0 0 AC 02 September 2010 Page 15 USER NOTES...

Page 16: ...arters 140 Harrison Avenue Roseland NJ 07068 1239 800 526 2559 www amano com This manual is applicable to the Amano Multi discipline Readers MDR900 5 0 AC 06 and MDK900 5 0 AC 06 The last two digits o...

Reviews: