Key

 

Output

 

1001 

1010 

1011 

Table 1:  Fixed Length Key Output Mode 

Setting the Fixed Length Mode 

The number of keys to be buffered and the parity option in the Fixed Length Mode is 
set as follows:  

1. 

Press and hold down key '2' for 3 seconds.  The Status LED enters a fast flash 
Mode and emits a long beep. 

2. 

Enter a 3 digit number followed by the Hash Key (#).  The first 2 digits specify the 
key buffer length and must be in the range 00 to 11 (eleven).  The third digit must 
be a „0‟ where there is no parity and „1‟ where parity is added. 

NOTE: 

If ‘00’ is entered for the key buffer length then the Key Mode reverts to PIN 
Mode. 

3. 

On acceptance of the setting the Status LED changes to Green. 

4. 

If the settings are rejected the Status LED changes to Red. 

Single Key 8-bit Burst Mode 

To select this mode

, specify the Fixed Length Buffered Mode to be “018”.  This mode 

reports each single key press as 8-bit code.  Use Single Key 8-bit Burst Mode when 
using Multi-discipline Readers in PAC Mode or TAG+PIN Mode. 

Key

 

Output

 

11110000 

11100001 

11010010 

11000011 

10110100 

10100101 

10010110 

10000111 

01111000 

01101001 

01011010 

01001011 

Table 2:  Single Key 8-bit Burst Mode 

Setting Single Key 8-bit Burst Mode 

1. 

Press and hold down key '2' until the Reader beeps continuously. 

2. 

Enter 

„018‟ and finish by pressing the Hash Key (#). 

Summary of Contents for MDK900-5-0-AC Series

Page 1: ...similar to IP54 The Multi discipline Readers are therefore sealed potted against water Input Voltage Rating 8 V DC to 14 V DC polarity sensitive Power Requirements Current mA Power W Supply Voltage 1...

Page 2: ...onnect the Purple and Gray wires to a Dry Contact Input On Amano Systems it is unnecessary to connect these lines as the Software handles the Anti tamper MDK900 model only Keypad 12 Alphanumeric keys...

Page 3: ...Communications Distance Install the Multi discipline Readers no further than 150 m 164 yd from the Host unit The cable individual conductor cross sectional area should not be less than 0 2 mm 2 0 000...

Page 4: ...tember 2010 Page 4 ELECTRICAL CONNECTIONS Connecting the Multi discipline Reader Figure 1 to Figure 5 show typical connections for the Multi discipline Reader Figure 1 Multi discipline Reader Connecte...

Page 5: ...MDR300 0 0 AC 02 September 2010 Page 5 Figure 2 Multi discipline Reader Connected to the Nexus 220 Controller...

Page 6: ...MDR300 0 0 AC 02 September 2010 Page 6 Figure 3 Multi discipline Reader Connected to the Amano MfT...

Page 7: ...MDR300 0 0 AC 02 September 2010 Page 7 Figure 4 Multi discipline Reader Connected to the Amano TA or Amano iTA...

Page 8: ...MDR300 0 0 AC 02 September 2010 Page 8 Figure 5 Multi discipline Reader Connected to the Amano RL Amano RS and Amano RH...

Page 9: ...M Use Only The Multi discipline Readers offer four different Output Mode Combinations Select the Output Mode by doing the following 1 On the back of the Multi discipline Reader locate and bridge the t...

Page 10: ...utton Keypad is used to enter 5 digit PIN codes in the range 00000 to 65535 Wiegand protocol constraints disallow PIN codes from 65536 to 99999 In this case the Status LED turns Red and the Buzzer act...

Page 11: ...is entered for the key buffer length then the Key Mode reverts to PIN Mode 3 On acceptance of the setting the Status LED changes to Green 4 If the settings are rejected the Status LED changes to Red...

Page 12: ...beep for 2 seconds When the Multi discipline Reader passes the Self test it emits two short beeps each 200 ms in duration separated by a 200 ms inter beep pause When the Multi discipline Reader is co...

Page 13: ...MDR300 0 0 AC 02 September 2010 Page 13 USER NOTES...

Page 14: ...MDR300 0 0 AC 02 September 2010 Page 14 USER NOTES...

Page 15: ...MDR300 0 0 AC 02 September 2010 Page 15 USER NOTES...

Page 16: ...arters 140 Harrison Avenue Roseland NJ 07068 1239 800 526 2559 www amano com This manual is applicable to the Amano Multi discipline Readers MDR900 5 0 AC 06 and MDK900 5 0 AC 06 The last two digits o...

Reviews: