Make Electrical Connection

1. Disconnect power. 

2. Use UL listed wire connectors and connect white wires (A) 

together.

3. Use UL listed wire connectors and connect black wires (B) 

together.

4. Connect green (or bare) ground wire from power supply to 

green ground screw in terminal box and securely tighten.

5. Install terminal box cover.

6. Reconnect power.

Complete Installation

1. Replace the 2 bottom panels.

a. Place the back of the panel into the rear channel and 

push the panel toward the back of the range hood until 
the tabs on the front of the panel clear the front mounting 
flange.

b. Push the front of the panel up into the front mounting 

flange until the panel tabs align with the slots in the front 
mounting flange. Release the panel so the tabs lock the 
panel in place.

2. Replace grease filter. See the “Range Hood Care” section.

3. Check the operation of the range hood fan and light. See 

“Range Hood Use” section.

If range hood does not operate, check to see whether a 
circuit breaker has tripped or a household fuse has blown. 
Disconnect power and check wiring connections. 

NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.

A. White wires
B. Black wires

C. UL listed wire connector
D. Green (or bare) ground wire

E. Home power supply cable or 

power cord accessory kit

F. UL listed or CSA approved 

½" strain relief

G. Green ground screw

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

A

B

C

D

E

F

G

WARNING

Fire Hazard

Electrically ground the blower.

Use copper wire.

Connect ground wire to green ground screw in 
terminal box.

Failure to do so can result in death, fire, or 
electrical shock.

Summary of Contents for UXT5230AYB

Page 1: ...lpool ca HOTTE D ASPIRATION DE 30 76 2 CM ET 36 91 4 CM Instructionsd installationetGuided utilisationetd entretien Au Canada pour assistance installation ou service composer le 1 800 807 6777 ou visi...

Page 2: ...installation 27 UTILISATION DE LA HOTTE 28 Commandes de la hotte de cuisini re 28 ENTRETIEN DE LA HOTTE 28 Nettoyage 28 SCH MA DE C BLAGE 30 ASSISTANCE OU SERVICE 31 Au Canada 31 Accessoires 31 GARAN...

Page 3: ...ardous or explosive materials and vapors CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside do not vent exhaust air into spaces within walls or ceilings attics or i...

Page 4: ...crews with washers and nuts to attach filler strips LocationRequirements IMPORTANT Observe all governing codes and ordinances It is the installer s responsibility to comply with installation clearance...

Page 5: ...the vent system enters the heated portion of the house Makeup Air Local building codes may require the use of makeup air systems when using ventilation systems greater than specified CFM of air moveme...

Page 6: ...for joining copper to aluminum Follow the electrical connector manufacturer s recommended procedure Aluminum copper connection must conform with local codes and industry accepted wiring practices Wire...

Page 7: ...ne on the underside of the cabinet Mark the point on this line that is 2 2 cm from back wall Drill a 1 3 2 cm diameter hole through the cabinet at this point To wire through wall 1 Mark a line distanc...

Page 8: ...ide of the top of cabinet 3 Use a compass or a circle template to draw a circle with a diameter that is 0 64 cm larger than the vent 4 Use saber or keyhole saw to cut the circular vent opening Style 3...

Page 9: ...into place 7 Remove vent knockouts depending on your installation requirements Round vent system installations Remove top rectangular and round vent knockouts Rectangular vent system installations Fo...

Page 10: ...n on ordering NOTE Do not reconnect power until the installation is complete 2 Remove the screw from the terminal box cover Remove terminal box cover and set aside 3 Remove the power supply knockout f...

Page 11: ...2 Replace grease filter See the Range Hood Care section 3 Check the operation of the range hood fan and light See Range Hood Use section If range hood does not operate check to see whether a circuit...

Page 12: ...paper towels To avoid damage to the stainless steel do not use cleaners that contain chlorine Cleaning Method Rub in direction of grain to avoid scratching or damaging the surface For stainless steal...

Page 13: ...rew into the filter retainer Replacing the Halogen Lamp Turn off the range hood and allow the halogen lamp to cool To avoid damage or decreasing the life of the new lamp do not touch lamp with bare fi...

Page 14: ...A 110 Watts 27 5 10 Ohms 55 7 10 Ohms Motor Characteristics Power Supply 120 VAC Frequency 60 Hz Amperage Wattage Rating Motor Resistance Red Brown Red Black Red Gray 86 8 10 Ohms W Common BK Line BK...

Page 15: ...company in your area you can also look in your telephone directory Yellow Pages For further assistance If you need further assistance you can write to Whirlpool Corporation with any questions or conce...

Page 16: ...ce by an authorized Whirlpool servicer is not available 10 The removal and reinstallation of your major appliance if it is installed in an inaccessible location or is not installed in accordance with...

Page 17: ...n cas de non respect des instructions Votre s curit et celle des autres est tr s importante Nous donnons de nombreux messages de s curit importants dans ce manuel et sur votre appareil m nager Assurez...

Page 18: ...que d incendie et vacuer ad quatement les gaz veiller acheminer l air aspir par un conduit jusqu l ext rieur ne pas d charger l air aspir dans un espace vide du b timent comme une cavit murale un plaf...

Page 19: ...ion des tringles d appui Exigencesd emplacement IMPORTANT Observer les dispositions de tous les codes et r glements en vigueur C est l installateur qu incombe la responsabilit de respecter les distanc...

Page 20: ...ment d isolation thermique pour minimiser la conduction de chaleur par l interm diaire du conduit d vacuation de l int rieur de la maison l ext rieur Le clapet anti retour doit tre plac du c t air fr...

Page 21: ...u le sommet achat s par B Bouche de d charge murale avec clapet achat s par C Entre 24 61 cm min et 30 76 2 cm max au dessus de la surface de cuisson Composant Rond Coude 45 2 5 pi 0 8 m Coude 90 5 0...

Page 22: ...vec la demande de courant de l appareil sp cifi e sur la plaque signal tique La plaque signal tique de l appareil est situ e derri re le filtre sur la paroi arri re de la hotte Le calibre des conducte...

Page 23: ...r la face inf rieure du sommet du placard vacuation par le mur D coupage d une ouverture rectangulaire de 3 x 10 8 9 cm x 26 7 cm dans le mur 1 Mesurer 2 lignes de 0 9 cm et 3 9 8 cm en descendant par...

Page 24: ...er l ouverture circulaire pour le passage du conduit d vacuation Installation du conduit d vacuation 1 Installer le conduit d vacuation travers l ouverture d coup e dans le placard mural ou le mur Ach...

Page 25: ...8 3 x 25 4 cm selon la configuration de votre installation La fixer la hotte l aide des vis de 3 5 x 5 mm fournies et retirer le ruban adh sif de l obturateur registre REMARQUE La plaque de montage de...

Page 26: ...on avant d avoir compl tement termin l installation 2 ter la vis du couvercle du bo tier de connexion Retirer le couvercle du bo tier de connexion et le mettre de c t 3 ter l opercule pour le passage...

Page 27: ...graisse Voir la section Entretien de la hotte 3 Contr ler le fonctionnement du ventilateur de la hotte et de la lampe Voir la section Utilisation de la hotte Si la hotte ne fonctionne pas d terminer...

Page 28: ...ment la hotte et les filtres graisse en suivant les instructions suivantes R installer le filtre graisse avant de faire fonctionner la hotte Surfaces externes IMPORTANT Ne pas utiliser de tampons de r...

Page 29: ...cher la patte de retenue du filtre Elle reviendra alors en place et fixera le filtre 4 R installer la vis dans la patte de retenue du filtre Remplacement de la lampe halog ne Interrompre l alimentati...

Page 30: ...e 3 Vitesse 2 Vitesse 1 MAR BL GRIS N Fonctionnement du commutateur L 1 Lampes 120 V 1 5 Ohms L 2 Vitesse 1 120 V 1 5 Ohms L 3 Vitesse 2 120 V 2 0 Ohms 2 5 Ohms 120 V Vitesse 3 L 4 Rouge Gris 86 8 10...

Page 31: ...ue ce gros appareil m nager est utilis et entretenu conform ment aux instructions jointes ou fournies avec le produit Whirlpool Corporation ou Whirlpool Canada LP ci apr s d sign es Whirlpool paiera p...

Page 32: ...ATIONS PEUVENT NE PAS S APPLIQUER DANS VOTRE CAS CETTE GARANTIE VOUS CONF RE DES DROITS JURIDIQUES SP CIFIQUES ET VOUS POUVEZ GALEMENT JOUIR D AUTRES DROITS QUI PEUVENT VARIER D UNE JURIDICTION UNE AU...

Reviews: