Amana Room Air Conditioner & Heat Pump Use And Care Manual Download Page 4

4

Annual Inspection

It is suggested that your unit be inspected by your dealer or

servicer once a year.  It is advisable to have the outer case

removed and the unit thoroughly cleaned.

Note:  The life of your unit may be greatly reduced if you live
in a salt air or other corrosive type environment.  Under these
conditions, the unit should be removed from its case and
completely cleaned at least once a year.  At that time any
scratches or blisters on the painted surfaces should be
sanded and repainted.  Placing an algaecide tablet in the
outdoor side of the unit’s basepan is suggested in humid
areas where algae formation is common.  We recommend the
following algaecide cleaners: PanGuard

®

 by Control Released

Technologies, Inc. and CDC Anti-Clog

®

 by Virginia KMP.

Front Grille and Filter Removal

The front contains an air filter that can be removed. To clean

the filter, use the following method for filter removal.

Grasp exhaust grille and hinge up.

Grasp filter handle and slide filter out of unit.

Optional Charcoal Air Filter Installation

Remove charcoal air filter from plastic bag. Insert three tabs

on right side of filter into three slots on filter frame. Carefully

bow middle of filter until two tabs on filter can be inserted into

two slots on filter frame. Relax bow.

Reinstall air filter by reversing removal procedure.

Front Grille and Cabinet Cleaning

Grille and cabinet may be cleaned with warm water and mild

soap or detergent. Cleaning and polishing compounds are not

recommended, as they may damage plastic surfaces.

Air Filter Cleaning

A dirty air filter reduces operating efficiency of unit. Filter

should be inspected at least once every week during opera-

tion. Clean filter with vacuum cleaner or wash in warm water

and mild detergent. Filter should be thoroughly dried before

replacing in unit. Do not operate unit without filter in place.

Fan Motor Care

The fan motor is permanently lubricated for long life. There is

no need to oil the motor.

Slide-out Chassis Removal from Outer Case

1. Hinge front  grille up.
2. Remove air filter by grasping handle and lifting up.
3. Remove 3 screws (1 each side and 1 behind filter) holding

plastic front to unit and remove front.

4. If the unit has a screw holding the basepan clip to the

chassis, remove the screw.

CAUTION

To reduce the risk of personal injury, be sure to
have sufficient help when moving your unit.  A
room air conditioner can weigh between 70 and
240 pounds.

5. Using basepan handle, pull chassis straight out, slowly

and evenly, until approximately 9-12 inches extends from

outer case. Use both hands to grasp basepan and pull

remaining chassis from outer case.

NOTE: 

Basepan clip is shipped in plastic bag with mounting

screw and condensate drain cup. Install clip after reinserting

chassis into outer case to prevent accidental chassis re-

moval.

Summary of Contents for Room Air Conditioner & Heat Pump

Page 1: ...counter problems during installation call our consumerinformationlinetoll freeat1 877 376 0214 If your problem cannot be resolved by phone contact an authorizedAmana brandservicer Contactandservice will be at your expense IO 372A 2010GoodmanCompany L P Effective May2010 SafetyInformation Besureelectricalserviceisadequateforchosenmodelofair conditioner Complete electrical rating for unit is found o...

Page 2: ...sreceiptforfuturereference Youmay alsowanttorecordinthespaceprovidedthedatepurchased and the selling dealer OWNER S PRODUCT IDENTIFICATION MODEL NUMBER SERIAL NUMBER MANUFACTURING NUMBER Owner s Name Address City State Zip Date of Purchase Authorized Dealer Address City State Zip Phone Number To avoid death personal injury or property damage due to electrical shock Observe all local codes and ordi...

Page 3: ...d with your unit Unit without a window mounting kit No window mounting kit is supplied with the unit These models are designed for mounting through an opening in a wall These units can be adapted to windowinstallationbypurchasinganoptionalwindow mountingkit Consultyourdealertochoosethekitthat is appropriate for your model and installation RoomHeatPumps Heatpumpsworkbymovingheatinsteadofcreatingit ...

Page 4: ...terbyreversingremovalprocedure Front Grille and Cabinet Cleaning Grille and cabinet may be cleaned with warm water and mild soapordetergent Cleaningandpolishingcompoundsarenot recommended as they may damage plastic surfaces Air Filter Cleaning A dirty air filter reduces operating efficiency of unit Filter should be inspected at least once every week during opera tion Clean filter with vacuum clean...

Page 5: ...om the indoor air condensate is channeled to the outdoor side of the unit The outdoor fan blade has a slinger ring attachedtoitthatdipsintothewaterandslingsthewateronto the outdoor coil surface This is the sound of water you hear duringnormaloperation Thewaterquicklyevaporatesonthis warmsurfaceandimprovestheefficiencyofyourairconditioner In normal conditions the unit can evaporate the water as fas...

Page 6: ...y fuse or circuit breaker Thesemodelsshouldbeinstalledon their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possible fire hazard from overheating wires CAUTION Do not under any circumstances cut or remove the third ground prong from the power cord Do not change the plug on the power cord of this air conditioner Alu...

Page 7: ...p mounting rail Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 4 Type C 7 Type E Bolt 2 nuts 2 PARTS INCLUDED Appearance may vary Installation Instructions Type D 6 Type E 4 Type F 2 Installation Instructions ...

Page 8: ...H Long enough to fit inside the window frame THICKNESS Todeterminethethickness placea piece of wood on the stool to make it 1 2 higher than the top of the storm window frame Attach securely with nails or screws provided by the installer 2 STORM WINDOW REQUIREMENTS Remove the locking screw and locking bracket from the lower frame Save to reinstalllater Remove the ground screw and save to reinstalll...

Page 9: ...ews Drill pilot holes if necessary Make sure the bolts and nuts are all of the way in both the left and right V supports Position the V supports on the case bottom so that they will be near the outside wall Attach a V support to each side of the bottom of the case using type C screws 3 on each side C B A 6 Bolt and nut V support 4 type E screws S tool Make sure the bolts and nuts are all of the wa...

Page 10: ...ertical window sashes Drill pilot holes and attach the top and bottom corners with 4 type D screws F E D 6 Type D screw Type D screw Type D screw Top mounting rail Type D screw INSTALL SUPPOR T BRACKETS AND THE FOAM TOP WINDOW GAS KET Attach the support brackets with two type D screws one on each side Cut the foam top window gasket to the window width Stuff the foam between the glass and the windo...

Page 11: ... the air discharge area Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case Push the grille frame in And install the 2 side screws at bottom left and right side of front panel Secure the front grille frame to the case with one type C screw Reinstall the filter Reinstall the inlet grille Connect power J I H G 8 Guide the le...

Page 12: ...ve carpentry and or masonry experience Thru wall installations performed by inexperienced or unqualified individuals can result in costly damage to home or result in equipment malfunction that could cause property damage personal injury or death CAUTION Air Conditioner Dimensions The following figures show the outside dimensions of air conditioner with chassis installed and dimensions of outer cas...

Page 13: ...ming lumber 26 1 8 17 Framed Finished Opening brick veneer or frame wall construction Placement of Outer Case in Opening Place outer case in opening flush against one side of opening Use carpenter s level and ensure case is level from side to side and has a 3 8 inch slope from front to back back of case must be 3 8 inch lower than front to ensure proper condensate drainage If needed use shims to l...

Page 14: ... 9 inches The side louvers in outer case provide ventilation to air con ditioner compressor and fan motor and must not be blocked When installing unit in a wall over 9 inches thick provisions must be made in wall opening to ensure free air flow to the side louvers This can be accomplished by chamfering the vertical portions of the outside opening as shown Ventilation louvers on top of case must no...

Page 15: ...n the unit or the INCREASE DECREASE pads on the remote control will set the delay time when using the TIMER 0 5 24 hr The SET light will turn on while setting r FanSpeedPads Use to set the fan speed to LOW MED HIGH or AUTO on the unit NOTE On the remote control use the fan speed IN CREASE DECREASE pads to set the fan speeds to LOW MED or HIGH Use the AUTO pad to turn Auto fan on s Mode Pad Use to ...

Page 16: ...s off and then turned on while set to a COOL setting or if it is turned from a fan setting to a COOL setting it may take approximately 3 minutes for the compressor to start and cooling to begin Cooling Descriptions For Normal Cooling Select the COOL mode and HIGH or MED fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH fan with a lower set temperature For Quieter ...

Page 17: ...g or adding condensate drain cup Check with dealer to determine proper capacity unit for application MOUNTING SUPPORT NOT INSTALLED Storm window frame installed in window Some models require removal of storm window frame before installation FROST ON INDOOR COIL Dirty air filter Normal for low outdoor temperatures Clean air filter by vacuuming or washing with water and mild soap Turning Temperature...

Page 18: ... enclosed with unit Keep accurate records of service calls including what was done servicer s name and date of service AnyQuestions Mostquestionscanbeansweredbyyourlocaldealer Ifyou have other matters that cannot be resolved locally or you need additional information regarding other heating and cooling products offered by us please call CONSUMERINFORMATIONLINE AMANATOLLFREE 1 877 376 0214 U S and ...

Page 19: ... locate an authorized Amana brand servicer contact Goodman Company Consumer Affairs at the number or address found at the bottom of this certificate Goodman will not pay for electricity or fuel costs or increases in electricity or fuel costs for any reason including additional or unusual use of supplemental electric heat This warranty does not cover lodging WARRANTY LIMITATIONS WE ARE NOT RESPONSI...

Page 20: ...ctive part must be returned to an Amana brand heating and air conditioning products distributor by an authorized Amana brand servicer and all warranty service must be performed by an autho rized Amana brand servicer To locate an authorized Amana brand servicer contact Goodman Company Consumer Affairs at the number or address found at the bottom of this certificate Model Serial ____________________...

Reviews: