5-14
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Fan motor or
oven lamp do
not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check fan motor.
Defective fan motor.
Replace fan motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
NOTE : Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5¡C temperature rise is normal condition.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Abnormal
Defective PCB
assembly.
Replace PCB
assembly.
Normal
Abnormal
Measure the
output power.
Defective
magnetron.
Replace
magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Disconnect the
wire leads from
relay 2 and
check on and off
time with
multitester.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Blower motor
or oven lamp
do not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check blower motor.
Defective blower motor.
Replace blower motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
NOTE : Simple test of power output-conducted by heating one liter water for one min. if available.
Minimum 8.5°C temperature rise is normal condition.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Abnormal
Defective PCB
assembly.
Replace PCB
assembly.
Normal
Abnormal
Measure the
output power.
Defective
magnetron.
Replace
magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Disconnect the
wire leads from
relay 3
and check
on and off time
with multitester.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Blower motor
or oven lamp
do not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check blower motor.
Defective blower motor.
Replace blower motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Abnormal
Defective PCB
assembly.
Replace PCB
assembly.
Normal
Abnormal
Measure the
output power.
Defective
magnetron.
Replace
magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Blower motor
or oven lamp
do not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check blower motor.
Defective blower motor.
Replace blower motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Abnormal
Defective PCB
assembly.
Replace PCB
assembly.
Normal
Abnormal
Measure the
output power.
Defective
magnetron.
Replace
magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
1. Setting time
does not count
down when
touching START
pad.
2. Blower motor
or oven lamp
do not turn on.
No continuity.
Continuity.
Continuity
Defective PCB
assembly.
Loose connection.
Replace PCB
assembly.
Connect them
tightly.
No continuity
Abnormal
Check blower motor.
Defective blower motor.
Replace blower motor.
Abnormal
Normal
Check oven lamp.
Defective oven lamp.
Replace oven lamp.
Defective
secondary switch.
Replace
secondary switch.
Check continuity
of secondary
switch (with
door closed).
Check the con-
nection between
CN1 connector
and PCB
assembly.
(TROUBLE 3) Display shows all figures set, but oven does not start cooking while desired
program times are set and START pad is touched.
(TROUBLE 4) Oven seems to be operating but little heat is produced in oven load.
CONDITION
CHECK
RESULT
CAUSE
REMEDY
Output is low
Lower than 90% of
rating voltage.
Normal
Abnormal
Defective PCB
assembly.
Replace PCB
assembly.
Normal
Abnormal
Measure the
output power.
Defective
magnetron.
Replace
magnetron.
Decrease in power
source voltage
with load.
Suggest customer
contact local
electric power
utility co. or
qualified
electrician.
Check the
power source
voltage.
Summary of Contents for RCS10A
Page 17: ...SCHEMATIC DIAGRAM 4 11 ...
Page 37: ...6 4 2012 2000 2400 2005 2006 2381 W130 W102 CONTROL PANEL PARTS MODEL RCSPBDA RFS12G EV ...
Page 38: ...6 5 2012 2400 2005 2006 2381 W130 2000 2002 W102 CONTROL PANEL PARTS MODEL RCS10PBDA EV ...
Page 39: ...2004 2000 2381 2002 2006 W130 W102 CONTROL PANEL PARTS MODEL RCS10A RCS10MPA 6 6 EV ...