ACCESSORY INSTALLATIONS
32
9. Replace the retaining ring back on the conduit clamp
inside the metal box and tighten the ring securely.
10. Insert the three wires extending from the metal box into
the incoming power opening on the unit so that approxi-
mately 20 inches of the wires protrude through the open-
ing.
11. Attach the metal box to the chassis with the two screws
provided.
12. Insert the wire tie into the 3/16 inch diameter hole lo-
cated just above the incoming power opening. Tie all
wires together securely with the wire ties.
Control Panel
Base Pan
Junction Box
Metal Box Location
Back of
Control Panel
Wire Tie
Electrical Supply
Wires
Right Side of
Chassis
3/16 Inch
Diamenter
Hole
Electrical Wiring Routing
208/230 Volt Units
1. Remove and discard the white lead from the wire as-
sembly.
2. Connect the black lead to the line 2 terminal on the
control board.
3. Connect the red lead to the common ( C ) terminal on
the capacitor.
4. Connect the ground wire to the partition panel where the
ground wire on the power cord was located. Use the
supplied green ground screw.
5. Connect the red lead in the wire assembly at the junc-
tion box to the red lead of the field power source.
6. Connect the black lead in the wire assembly at the junc-
tion box to the black lead of the field power source.
7. Connect the ground wire of the field power source to the
ground wire of the wire assembly at the junction box.
8. Install the junction box cover plate.
9. Reinstall the control panel assembly.
265 Volt Units
1. Remove and discard the red lead from the wire assem-
bly.
2. Connect the black lead to the center terminal of the fuse
holder.
3. Connect the white lead to the common ( C ) terminal on
the capacitor.
4. Connect the ground wire to the partition panel where the
ground wire on the power cord was located. Use the
supplied green ground screw.
5. Connect the white lead of the wire assembly at the junc-
tion box to the white lead of the field power source.
6. Connect the black lead of the wire assembly at the junc-
tion box to the black lead of the field power source.
7. Connect the ground wire of the field power supply to the
ground wire of the wire assembly at the junction box.
8. Install the junction box cover plate.
9. Reinstall the control panel assembly.
Summary of Contents for R-22