Transportation Damage

All units are securely packed in shipping containers
approved by the International Safe Transit Association.
The carton should be checked upon arrival for external
damage. If damage is found, a request for inspection by
carrier agent should be made in writing immediately.

The unit should be carefully inspected upon arrival for
damage and bolts or screws which may have loosened in
transit. In the event of damage, the consignee should:

1. Make notation on delivery receipt of any visible

damage to shipment or container.

2. Notify carrier promptly and request an inspection.

3. In case of concealed damage, carrier should be

notified as soon as possible-preferably within 5 days.

4. File the claim with the following supporting docu-

ments within the 9 month statute of limitations.

a. Original Bill of Lading, certified copy, or indemnity

bond.

b. Original paid freight bill or indemnity in lieu thereof.

c. Original invoice or certified copy thereof, showing

trade and other discounts or reductions.

d. Copy of the inspection report issued by carrier

representative at the time damage is reported to
the carrier. The carrier is responsible for making
prompt inspection of damage and for a thorough
investigation of each claim. The distributor or manu-
facturer will not accept claims from dealers for
transportation damage.

NOTE: When inspecting the unit for transportation dam-
age, remove all packaging materials. Recycle or dispose
of the packaging material according to local codes.

III. Rigging and Handling

CAUTION

To prevent property damage, the unit
should remain in an upright position
during all rigging and moving operations.
To facilitate lifting and moving when a
crane is used, place the unit in an adequate
cable sling.

Important: If using bottom discharge with roof curb,
ductwork should be attached to the curb prior to installing
the unit. Ductwork dimensions are shown in Amana roof
curb installation instructions.

Refer to the Amana Roof Curb Installation Instructions for
proper curb installation. Curbing must be installed in
compliance with the National Roofing Contractors Asso-
ciation Manual.

Lower unit carefully onto roof mounting curb. While rig-
ging unit, center of gravity will cause condenser end to be
lower than supply air end.

Figure 1

 Rigging

Summary of Contents for PHB**C

Page 1: ...n manual adjacent to the unit RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION Remember itisyourresponsibilitytoinstalltheproduct safely and to know it well enough to be able to instruct a customer in its...

Page 2: ...efects or other reproductive harm Locating The Unit WARNING Topreventdeath personalinjury property damage or equipment damage the following points must be observed when installing the unit All Install...

Page 3: ...pection report issued by carrier representative at the time damage is reported to the carrier The carrier is responsible for making prompt inspection of damage and for a thorough investigationofeachcl...

Page 4: ...de at the heater accessory box If no heater is installed the thermostat wiring will bemade to the low voltage control board See the unit wiring diagram for electrical connections O R W Y G O R W Y G F...

Page 5: ...de For knockout locations see dimension drawing on the SpecificationSheet UsetheSinglePointwiringkittoadd further flexibility to the installation wiring Unit Voltage The unit transformer is factory co...

Page 6: ...duct from the unit through a wall fabricated of combustible material may be installed with out clearance However minimum clearances for the unit must be observed as shown in Specification Sheet The o...

Page 7: ...WARNING To avoid death or personal injury due to electrical shock do not remove any internal compartment covers or attempt any adjustment CAUTION Verify proper operation after servicing VIII Sequence...

Page 8: ...cludes its own separate instructions Replacement Parts Refer to the description in the Parts Catalog when order ing any part Be sure to provide the unit model manufac turing and serial numbers with th...

Reviews: