background image

Component Specifications

RT1300057  Rev. 2

4

November 2000

Door Gasket

Door gaskets foamed in place between
inner door liner and door pan during
manufacturing.

If gasket is damaged, replace with appropriate service gasket kit (see Parts
Manual for kit part numbers) following instructions in kit.

Refrigerator and
freezer door

Foamed as an assembly during
manufacturing.

Inner door liner and outer door pan are not replaceable. If damaged, entire door
must be replaced.

!

WARNING

To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.

Summary of Contents for ARS2304A PARS2304AB0

Page 1: ... Percent Run Time 10 Cycles 24 hr 25 Refrigerator Compartment Average Food Temperature 3 F Freezer Compartment Average Food Temperature 3 F Ambient F 65 90 110 65 90 110 65 90 110 65 90 110 65 90 110 ARS2304A 1 4 2 4 35 55 100 32 28 0 36 39 38 2 2 1 ARS2604A 1 4 2 4 34 60 100 31 23 0 36 37 35 2 1 3 Temperature Relationship Test Chart T 1 Outlet 3 F T 2 Inlet 3 F T 3 Suction Line 7 F Average Total ...

Page 2: ...ttings 1 4 7 Closing temperatures 47 F 40 F 30 F R0161092 Control freezer temperature Settings 1 in 1 out 4 in 4 out 7 in 7 out Temperatures 21 0 F 4 5 F 13 3 F 5 9 F 9 8 F 11 0 F B2150504 Drier Drier must be changed every time the system is opened for testing or compressor replacement Desiccant 20 8 x 12 4AXH 7 M S Grams 12049801 Heater evaporator Volt Wattage Resistance 115 VAC 450 5 watts 29 5 ...

Page 3: ...econds Short time trip amps 77 F 25 C 115 VAC 3 51 amps 142 F 61 C 9 257 F 125 C 5 10 seconds 5 14 amps 10097202 Relay ptc Resistance With power off check Across terminals 2 3 Shorted Open 4 6 ohms 0 ohms Very high or infinite ohms 12466102 Switch refrigerator freezer light Type Volt Current DPST NC 125 VAC 5 0 amps 12017823 Thermostat Volt Watt Current Resistance across terminals Above 48 5 F Bel...

Page 4: ...tor and freezer door Foamed as an assembly during manufacturing Inner door liner and outer door pan are not replaceable If damaged entire door must be replaced WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed...

Page 5: ...2604A PARS2604AW0 WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization ...

Page 6: ...604A PARS2604AW0 WARNING To avoid risk of electrical shock that can cause death or severe personal injury disconnect unit from power before servicing unless tests require power Discharge capacitors through a 10 000 ohm resistor before handling Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization ...