Amana Technical Information
³
Refrigerator
November 2000
1
RT1300057 Rev. 2
ARS2304A
PARS2304AB0
ARS2604A
PARS2604AB0
ARS2304A
PARS2304AC0
ARS2604A
PARS2604AC0
ARS2304A
PARS2304AW0
ARS2604A
PARS2604AW0
•
Due to a possibility of personal injury or property damage, always contact an authorized technician for servicing
or repair of this refrigerator.
•
Refer to Service Manual RS1300004 for installation, disassembly, safety, testing and troubleshooting
information.
Model
ARS2304A
ARS2604A
Capacity
23.2 cu ft
25.9 cu ft
Electrical requirements
separate circuit
115 VAC 60 Hz
15 amps
115 VAC 60 Hz
15 amps
Refrigerant type
R134a
R134a
Width
without side extrusions
35.75
35.75
Depth
without handle
includes door extrusions
29.75
32.5
Height
including top hinge cap
68.5
68.5
No Load Performance Controls in Normal Position
Kw/24 hr ±0.4
Percent Run Time
±10%
Cycles/24 hr
±25%
Refrigerator
Compartment
Average Food
Temperature ±3°F
Freezer
Compartment
Average Food
Temperature ±3°F
Ambient °F
65°
90°
110°
65°
90°
110°
65°
90°
110°
65°
90°
110°
65°
90°
110°
ARS2304A
1.4
2
4
35
55
100
32
28
0
36
39
38
2
2
1
ARS2604A
1.4
2
4
34
60
100
31
23
0
36
37
35
2
1
-3
Temperature Relationship Test Chart
T-1 Outlet
±3°F
T-2 Inlet
±3°F
T-3 Suction Line
±7°F
Average Total
Wattage ±10%
Suction
Pressure ±2
PSIG
Head Pressure
±5 PSIG
Ambient °F
65°
90°
65°
90°
65°
90°
65°
90°
65°
90°
65°
90°
ARS2304A
-15
-17
-18
-16
78
100
153
163
0
1
85
124
ARS2604A
-14
-17
-20
-16
73
98
156
165
0
1
82
131
!
CAUTION
All safety information must be followed as provided in Service Manual RS1300004.
!
WARNING
To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before
servicing unless tests require power. Discharge capacitors through a 10,000-ohm resistor before handling. Wires
removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization.