background image

Component Specifications

!

WARNING

To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.

RT2310010   Rev. 1

May 2000

4

Converting from Natural Gas to LP Gas

Converting the Insta-Broil

1.  Remove or open oven door.
2.  Remove screws securing Insta-Broil

 bracket.

3.  Remove burner carefully, avoid damaging the ignitor

to expose burner spud. Remove the #52 natural gas
burner spud using a 5/16 socket wrench. Save #52
spud to reconvert if necessary in the future.

4.  Install the #58 LP/propane spud (wired to inlet pipe).
5.  Replace Insta-Broil

 burner and holding screws.

Converting Oven Burner for Use with LP/Propane

1.  Remove storage drawer.
2.  Locate and remove 2 screws attaching Z-shaped

cover plate.

•  Cover plate located in center, rear of storage

drawer cavity.

•  Removing cover plate exposes oven burner orifice

and air shutter.

A

B

C

A— Air Shutter Screw
B— Orifice Hood
C— Air Shutter

3.  Turn orifice hood clockwise until snug.

•  Do not over tighten orifice hoods. Orifice hoods can

damage LP pin.

4.  Replace cover plate and storage drawer.

Converting Surface Burners for Use with LP/Propane

1.  Remove 4 burner control knobs from range.

•  Expose 2 screws on burner control panel.

2.  Remove 2 screws from burner control panel.

•  Panel drops slightly after screws are removed.

3.  Grasp bottom of burner control panel, gently lift and

pull out panel until clear of burner valve stems.

•  After burner control panel clears valve stems,

continue to roll panel until free from range. Set
aside.

•  Gas valve and orifice hood are visible after burner

control panel is removed.

E

C

D

A

B

A— Burner Control Knob

D— Screw

B— Pivot Point

E— Orifice Hood

C— Burner Control Panel

4.  While facing range front, turn orifice hoods

counterclockwise 1½ to 2 turns or until snug.

•  Use ½ inch open end or 90° offset open end

wrench.

•  Do not over tighten orifice hoods. If orifice hoods

are over tightened, gas supply can be cut off or
orifice hoods can damage LP pin.

5.  Reassemble burner control panel after adjusting air

shutter.

Converting Pressure Regulator for LP/Propane

1.  Remove pressure regulator cap using a 7/8 inch

wrench.

2.  Reverse pressure regulator cap.

•  Cap must show “LP”.

3.  Place pressure regulator cap on pressure regulator

and tighten.

Adjusting Burner Flame

Properly adjusted burner flames are clean and blue with
a distinct inner cone approximately ½ inch long.

  If burner flame is blowing or noisy, reduce airflow to

burner.

  If burner flame is yellow and does not hold its shape,

increase airflow to burner.