Component Testing Information
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
May 2000
RT2310010 Rev. 1
3
Illustration
Component
Test Procedure
Results
0316220
Gas valve
Disconnect wiring to valve.
Measure resistance on bake circuit.
Measure resistance on broil circuit.
Continuity, If not replace.
Continuity, If not replace.
WARNING
!
Do not attempt to open valve with
120 VAC.
0308866
Pressure regulator
Verify gas pressure (WCP).
If on LP service verify proper gas
supply conversion.
6
"
Natural
10
"
LP/propane
0306428
H
R
A A
G
Shut off valve
Check to verify gas supply is turned
on.
0315960
5 K btu
0315961
9 K btu
0315962
12 K btu
270
°
valve
Verify gas is supplied.
Orifice adjusted for Natural or LP.
Adjust set screw for simmer control.
0316572
Spark 270
°
switch
Test for voltage at terminals.
Disconnect wiring and check for
continuity in LITE position.
120 VAC
Continuity in LITE position.
0316773
Spark ignition
electrode
Test for resistance of spark lead.
Test ignitor to chassis.
Continuity
No continuity from ignitor to chassis.
0315769
5 K btu
0315768
9 K btu
0315767
12 K btu
Top surface burner
Verify gas is supplied.
Verify burner cap is positioned
correctly.
Check for obstructions in burner ports.
Venturi
Shutter settings:
Nominal
Tol.
±
.125
"
1/8
"
.031
"
1/32
"
0315154
L
A
B
A1
B1
N
Spark module 4 + 0
Test for voltage at terminals L and N.
Check polarity and ground.
120 VAC
See wiring diagram.
31715201
LH
31715202
RH
Opening
Hinge
Carefully open the hinge fully, and
insert a wooden dowel or screwdriver
bit into opening.
Remove top and bottom screws
securing hinge.
Slide hinge top towards rear of unit
and guide hinge out through frame
opening or storage drawer.
CAUTION
!
Do not place hands in hinge area when
oven door is removed. Hinge can snap
closed and pinch hands or fingers.