AMVS80-U Heating Airflow Data

MODEL / TEMP RISE RANGE (MID RISE)

AMVS800604BU

20-50 (35)

AMVS800805CU

35-65-(50)

CFM

RISE

CFM

RISE

Recommended CFM & Expected Temperature Rise

1524

35

1760 (MAX 

CAPABLE CFM)

40

Minimum Recommended Heating CFM & Expected 

 

Temperature Rise

1067

50

1422

50

Maximum Recommended Heating CFM & Expected 

 

Temperature Rise

1760 (MAX 

 

CAPABLE CFM)

25

1760 (MAX 

CAPABLE CFM)

40

Note:

 To Set Heating CFM Using Push Buttons; 1) Scroll using Left or Right push buttons until gAF appears on the 7 segment display. 

 

2) Press & release center button & display will show current heating airflow expressed as a percentage of max CFM.3) Press & release 

Left or Right button until desired percentage appears. 4) Press & release center button once more to select the displayed percentage. 

 

5) CFM may be trimmed further by using the gTF menu.

Summary of Contents for AMVS80-U

Page 1: ...J NOx emission limit in SCAQMD Rule 1111 and SJVUAPCD Rule 4905 EMI line filter kit must be installed It is intended for field installation only on VS model Bluetooth capable Ultra Low NOx Gas Furnace...

Page 2: ...on NOx M Upflow Horizontal N Natural Gas C Downflow Horizontal X Low NOx U Ultra Low NOx Motor Cabinet Width V Variable Speed ECM ComfortBridge A 14 C 21 E Multi Speed ECM S Single Speed B 17 D 24 Gas...

Page 3: ...ly For altitudes 4500 above sea level see installation manual DOE AFUE based upon Isolated Combustion System ICS Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should...

Page 4: ...ance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National...

Page 5: ...d Heating CFM Expected Temperature Rise 1760 MAX CAPABLE CFM 25 1760 MAX CAPABLE CFM 40 Note To Set Heating CFM Using Push Buttons 1 Scroll using Left or Right push buttons until gAF appears on the 7...

Page 6: ...HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Tem...

Page 7: ...SWITCH ID BLOWER PRESSURE OR SERVICING WIRING EQUIPMENT GND ON SOME MODELS INTERNAL TO PROT DEVICE INTEGRATED CONTROL PK C USE COPPER CONDUCTORS ONLY AT LEAST 105 IT MUST BE REPLACED WITH WIRING MATER...

Page 8: ...uring Company L P Houston Texas Accessories Model Description MVK 01 Masonry Vent Kit TK 400 Twinning Kit Upflow applications only Minimum Filter Sizes Model AMVS80 0604BU AMVS80 0805CU Filter Size in...

Reviews: