Nomenclature

A

M

V

M

97

060

3

B

N

**

1

2

3

4

5,6

7,8,9

10

11

12

13,14

Brand

Engineering

A - Amana® Brand

Major / Minor Revisions

*  Not used for inventory control.

Configuration

NOx

M -  Upflow/Horizontal

   N - Low NOx

C - Downflow/Horizontal

Cabinet Width

Motor

   B - 17½”

   C - 21"

V - Variable Speed ECM / ComfortNet

   

   D - 24½"

E - Multi-Speed ECM 

S - Single Speed

Maximum CFM

   2 - 800 CFM

   4 - 1600 CFM

Gas Valve

   3 - 1200 CFM

   5 - 2000 CFM

M - Modulating

C - Two- Stage 

MBTU/h

S - Single Stage

040 - 40,000 BTU/h

060 - 60,000 BTU/h

AFUE

120 - 120,000 BTU/h

97 - 97% AFUE

96 -  96% AFUE

92 -  92% AFUE

Summary of Contents for ACVM97

Page 1: ...g two stage or single stage thermostats Self diagnostic control board with constant memory fault code history output to a dual 7 segment display Color coded low voltage terminals with provisions for e...

Page 2: ...trol Configuration NOx M Upflow Horizontal N Low NOx C Downflow Horizontal Cabinet Width Motor B 17 C 21 V Variable Speed ECM ComfortNet D 24 E Multi Speed ECM S Single Speed Maximum CFM 2 800 CFM 4 1...

Page 3: ...on System ICS Installer must supply one or two PVC pipes one for combustion air optional and one for the flue outlet required Vent pipe must be either 2 or 3 in diameter depending upon furnace input n...

Page 4: ...0 19 20 5 9 19 34 19 B C 23 2 1 2 2 6 5 9 19 23 24 31 A 21 2 14 23 1 1 28 2 1 2 2 2 6 1 26 23 Folded Flanges 22 Unfolded Flanges D Unfolded Flanges E Folded Flanges Air Discharge Air Discharge LEFT SI...

Page 5: ...nstallation on non combustible floors only A combustible floor sub base must be used for installations on combustible flooring 18 A 34 4 11 14 25 B Return 28 C 6 6 11 14 14 25 3 2 2 1 2 23 14 1 1 1 1...

Page 6: ...mal 1 316 55 Plus 10 887 594 Plus 10 1 448 50 C Minus 10 921 635 C Minus 10 1 250 57 Normal 1 023 705 Normal 1 389 52 Plus 10 1 125 776 Plus 10 1 528 47 D Minus 10 1 107 737 D Minus 10 1 256 57 Normal...

Page 7: ...F A Minus 10 780 492 A Minus 10 1 702 63 Normal 867 547 Normal 1 891 57 Plus 10 954 602 Plus 10 2 080 52 B Minus 10 1 044 748 B Minus 10 1 746 62 Normal 1 160 831 Normal 1 940 56 Plus 10 1 276 914 Plu...

Page 8: ...c ESP ACVM970803BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Rise F A Minus 10 562 365 A Minus 10 950 n a Normal 624 405 Normal 1...

Page 9: ...e F A Minus 10 706 472 A Minus 10 1 583 57 Normal 784 524 Normal 1 759 51 Plus 10 862 576 Plus 10 1 935 46 B Minus 10 970 670 B Minus 10 1 617 56 Normal 1 078 744 Normal 1 797 50 Plus 10 1 186 818 Plu...

Page 10: ...TU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 T...

Page 11: ...TO 60HZ 115 VAC 1 POWER SUPPLY WITH POWER BEFORE SERVICING WIRING TO UNIT MUST BE TO UNIT MUST BE PROPERLY POLARIZED EQUIPMENT GND FIELD SPLICE SWITCH TEMP SWITCH PRESSURE PROT DEVICE LOW VOLTAGE FIEL...

Page 12: ...manent Filter 0170K00000S Flush Mount Vent Kit 3 or 2 0170K00001S Flush Mount Vent Kit 2 AFE18 60A Fossil Fuel Dual Fuel Kit LPLP03 Low LP Gas Pressure Switch LPM 09 LP Conversion Kits Notes Indicates...