background image

USER MANUAL

SLO / SFLO115 SERIES 

OIL FIRED WARM AIR FURNACES

ALL SUMMERAIRE SLO115 / SFLO115 MODELS

ARE AIR CONDITIONING READY !

NOTICE TO HOMEOWNER

THIS FURNACE SHALL BE INSTALLED BY A CERTIFIED INSTALLER AND

WHERE REQUIRED BY LAW, A LICENSED TECHNICIAN

Save These Instructions For Reference

Summeraire Mfg.

Peterborough, Ontario

K9J 7B1

FOR SERVICE CALL:

INSTALLATION INFORMATION

  ______________________________  

_____________________________  

            Installing Contractor                                                   Telephone Number

  ______________________________  

_____________________________

            Unit Model Number                                                     Unit Serial Number

  

 ________________________________

              

                Installation Date

NOTICE TO HOMEOWNER

IF YOUR SUMMERAIRE SLO/SFLO SERIES OIL FURNACE HAS BEEN INSTALLED USING 

THE APPROVED SS1-C TJERNLUND SIDEWALL POWER VENTOR, IT IS YOUR

RESPONSIBILITY TO KEEP THE AREA AROUND THE OUTSIDE TERMINAL OF THE 

POWER VENTOR CLEAR OF SNOW – ICE AND DEBRIS

OCT., 2007R

Summary of Contents for SLO115 SERIES

Page 1: ...NSTALLATION INFORMATION _ ______________________________ _____________________________ Installing Contractor Telephone Number _ ______________________________ _____________________________ Unit Model Number Unit Serial Number _________________________________ Installation Date NOTICE TO HOMEOWNER IF YOUR SUMMERAIRE SLO SFLO SERIES OIL FURNACE HAS BEEN INSTALLED USING THE APPROVED SS1 C TJERNLUND S...

Page 2: ...in this unit Never leave paper rags or other combustibles around the furnace Only qualified or where required by law a licensed technician shall set up this unit and adjust controls DO NOT START THE OIL BURNER UNLESS THE BLOWER DOOR IS SECURED IN PLACE TO TURN THE BURNER OFF Turn the main oil burner switch to OFF Set the thermostat as far below room temperature as possible IF BURNER IS TO BE SHUT ...

Page 3: ...ply to the furnace Note Always keep oil supply valve shut off if burner is shut down for an extended period of time The nozzle should be replaced annually handle nozzle with care so that the inside surface tip is not scratched The electrodes should be cleaned and adjusted see oil burner manual supplied with the oil burner LUBRICATION Apply 2 3 drops of SAE 20 30 Non Detergent oil ONLY to the oil p...

Page 4: ...ure is not required operate the small rocker switch located on the power junction box Low speed will not operate AIR FILTER This furnace should never be operated without filters A DIRTY AIR FILTER CAUSES INEFFICIENCY AND HIGHER OPERATING COSTS Clean or replace filters each heating season or as required Filter specifications for the air filter installed in your Summeraire oil fired warm air furnace...

Page 5: ...nditions of this warranty are provided no later than thirty 30 days after the expiration of this warranty whichever shall first occur 8 No mechanically cooled air Originating in the return air duct shall be circulated over the heat exchanger of the furnace 9 The owner must provide proof that the appliance has been serviced annually including annual cleaning of the complete furnace and inspection o...

Reviews: