8
www.amana-hac.com
SS-
AMVM97
SS-
AMVM97
www.amana-hac.com
9
ACVM970603BNA
Cooling Speed
(@ .1" - .8" w.c. ESP)
ACVM970603BNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap
Adjust
High-Stage
CFM
Low-Stage
CFM
Tap
Adjust
High-Stage
CFM
Rise
(°F)
A
Minus 10%
590
390
A
Minus 10%
844
64
Normal
656
433
Normal
938
57
Plus 10%
722
476
Plus 10%
1,032
52
B
Minus 10%
711
487
B
Minus 10%
855
63
Normal
790
541
Normal
950
57
Plus 10%
869
595
Plus 10%
1,045
52
C
Minus 10%
875
617
C
Minus 10%
887
61
Normal
972
686
Normal
986
55
Plus 10%
1,069
755
Plus 10%
1,085
50
D
Minus 10%
1,076
725
D
Minus 10%
893
60
Normal
1,195
806
Normal
992
54
Plus 10%
1,315
887
Plus 10%
1,091
49
ACVM970803BNA
Cooling Speed
(@ .1" - .8" w.c. ESP)
ACVM970803BNA
Heating Speed
(@ .1" - .5" w.c. ESP; Rise Range: 35 - 65°F)
Tap
Adjust
High-Stage
CFM
Low-Stage
CFM
Tap
Adjust
High-Stage
CFM
Rise
(°F)
A
Minus 10%
562
365
A
Minus 10%
950
n/a
Normal
624
405
Normal
1,056
n/a
Plus 10%
686
446
Plus 10%
1,162
62
B
Minus 10%
727
494
B
Minus 10%
1,031
n/a
Normal
808
549
Normal
1,146
63
Plus 10%
889
604
Plus 10%
1,261
57
C
Minus 10%
895
610
C
Minus 10%
1,130
64
Normal
994
678
Normal
1,256
57
Plus 10%
1,093
746
Plus 10%
1,382
52
D
Minus 10%
1,059
706
D
Minus 10%
1,214
59
Normal
1,177
784
Normal
1,349
53
Plus 10%
1,295
862
Plus 10%
1,484
48
ACVM97 Airflow Data
Notes
•
All furnaces ship as high speed for cooling. Installer must adjust blower
speed as needed.
•
For most jobs, about 400 CFM per ton when cooling is desirable.
•
INSTALLATION IS TO BE ADJUSTED TO OBTAIN TEMPERATURE RISE WITHIN THE RANGE SPECIFIED ON THE RATING PLATE
.