Natural Gas BTU/h

² 

DOE AFUE based upon Isolated Combustion System (ICS)

³ 

Installer must supply one or two PVC pipes: one for combustion air (optional) and one for the flue outlet (required). 

 

Vent pipe must be either 2" or 3" in diameter, depending upon furnace input, number of elbows, length of run and installation (1 or 2 pipes). The optional Combustion Air Pipe is 
dependent on installation/code requirements and must be 2" or 3" diameter PVC.

⁴ 

Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs 

will require larger wire sizes.

⁵ 

Maximum Overcurrent Protection Device refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit breakers of the same size as noted.

Notes

• 

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

• 

Gas Service Connection ½" FPT

• 

Important: Size fuses and wires properly and make electrical connections in accordance with the National Electrical Code and/or all existing local codes.

• 

For bottom return: Failure to unfold flanges may reduce airflow by up to 18%. This could result in performance and noise issues.

• 

For servicing or cleaning, a 24" front clearance is required. Unit connections (electrical, flue and drain) may necessitate greater clearances than the minimum clearances listed 

above. In all cases, accessibility clearance must take precedence over clearances from the enclosure where accessibility clearances are greater.

ACVC96 

0403BNA

ACVC96

0603BNA

ACVC96

0804CNA

ACVC96

1005CNA

ACVC96

1205DNA

Heating Data

High Fire Input¹

40,000

60,000

80,000

100,000

120,000

High Fire Output¹

38,400

57,600

76,800

96,000

115,200

Low-Fire Steady-State Input¹

28,000

42,000

56,000

70,000

84,000

Low-Fire Steady-State Output¹

26,880

40,320

53,760

67,200

80,640

AFUE²

96

96

96

96

96

Temperature Rise Range (°F)

20 - 50

35 - 65

25 - 55

45 - 75

35 - 65

Vent Diameter³

2" - 3"

2" - 3"

2" - 3"

2" - 3"

2" - 3"

No. of Burners

2

3

4

5

6

Circulator Blower

Available AC @ 0.5" ESP

1.5 - 3

1.5 - 3

1.5 - 4

2 - 5

2 - 5

Size  (D x W)

10" x 8"

11" x 8"

11" x 10"

11" x 10"

11" x 11"

Horsepower @ 1075 RPM

½

½

¾

1

1

Speed

VS ECM

VS ECM

VS ECM

VS ECM

VS ECM

Electrical Data

Min. Circuit Ampacity⁴

7.8

7.8

10.6

14.4

14.4

Max. Overcurrent Device (amps)⁵

15

15

15

20

20

Shipping Weight (lbs)

116

119

143

145

158

Product Specifications

Summary of Contents for ACVC96

Page 1: ...ger Stainless steel secondary heat exchanger Two stage gas valve provides quiet economical heating Durable Silicon Nitride igniter Quiet two speed induced draft blower Utilizes ComfortNet communicatin...

Page 2: ...1 HASFK 2 HASFK 3 HASFK 3 HASFK High Altitude LP Gas Kit HASFK 1 HASFK 1 HASFK 2 HASFK 2 HASFK 3 LPLP03 Low LP Gas Pressure Switch LPM 08 LP Conversion Kits Accessories A C V C 96 040 3 B N A A 1 2 3...

Page 3: ...r all existing local codes For bottom return Failure to unfold flanges may reduce airflow by up to 18 This could result in performance and noise issues For servicing or cleaning a 24 front clearance i...

Page 4: ...tage Electrical Outlet Air Discharge Air Discharge Folded Flanges B 18 TOP VIEW FRONT VIEW RIGHT SIDE VIEW Air Return Air Discharge Model A B C D E ACVC960403BNA 17 14 14 14 16 ACVC960603BNA 17 14 14...

Page 5: ...ACVC960603BNA Cooling Speeds 1 8 w c ESP ACVC960603BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Low Stage CFM Rise F A Minus 10 5...

Page 6: ...ling Speeds 1 8 w c ESP ACVC961005CNA Heating Speed 1 5 w c ESP Rise Range 45 75 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Low Stage CFM Rise F A Minus 10 706 472 A Minus 10...

Page 7: ...5 1 767 1 283 60 Normal 1 399 1 000 Normal 1 860 1 350 57 Plus 5 1 469 1 050 Plus 5 1 953 1 418 55 Plus 10 1 539 1 100 Plus 10 2 046 1 485 52 D Minus 10 1 624 1 112 D Minus 10 1 726 1 249 62 Minus 5...

Page 8: ...BL O LED S DIAGNOSTIC 4 FS 1 BK 5 3 24 V THERMOSTAT CONNECTIONS NEUTRAL 1 3 2 LINE FUSE 4 2 3 A 24 V NO 2 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS LIMIT CONTROL AUXILIARY AUTO RESET PK W...

Reviews: