background image

2

www.amana-hac.com

SS-ACVC96

SS-ACVC96

www.amana-hac.com

3

Nomenclature

Model

Description

ACVC96 

0403BNA

ACVC96 

0603BNA

ACVC96 

0804CNA

ACVC96 

1005CNA

ACVC96 

1205DNA

CTK04

ComfortNet-Compatible Control

CVENT-2

Concentric Vent Kit (2") 

CVENT-3 

Concentric Vent Kit (3") 

CFSB17

Downflow Sub-Base 17.5"

---

---

---

CFSB21

Downflow Sub-Base 21"

---

---

---

CFSB24

Downflow Sub-Base 24"

---

---

---

---

RF000142

Drain Kit -Horizontal Left Vertical Flue

---

---

---

---

---

EFR02

External Filter Rack with 16"x25" Permanent Filter

---

---

0170K00000S

Flush Mount Vent Kit - 3" or 2" 

0170K00001S

Flush Mount Vent Kit - 2"

AFE18-60A

Fossil Fuel (Dual Fuel) Kit 

HASFK

High-Altitude Natural Gas Kit

HASFK-1

HASFK-1

HASFK-2

HASFK-3

HASFK-3

HASFK

High-Altitude LP Gas Kit

HASFK-1

HASFK-1

HASFK-2

HASFK-2

HASFK-3

LPLP03

Low LP Gas Pressure Switch

LPM-08

LP Conversion Kits

Accessories

A

C

V

C

96

040

3

B

N

A

A

1

2

3

4

5,6

7,8,9

10

11

12

13

14

Brand

Minor   Revision

A   -­‐   Amana®   Brand

   A   -­‐   Initial   Release
   B   -­‐   1st   Revision

Configuration
M   -­‐   Upflow/Horizontal

Major   Revision

C   -­‐   Downflow/Horizontal

   A   -­‐   Initial   Release
   B   -­‐   1st   Revision

Motor
V   -­‐   Variable   Speed   ECM   /   ComfortNet

NOx

E   -­‐   Multi-­‐Speed   ECM   

S   -­‐   Single   Speed

         N   -­‐      Low   Nox   (40ng/J)

Gas   Valve
M   -­‐   Modulating

S   -­‐   Single   Stage

Cabinet   Width

C   -­‐   Two   Stage   

H   -­‐   Convertible   Single   Phase

B - 17½"   

   C   -­‐   21"

D   -­‐   24½"

AFUE
92   -­‐   92%   AFUE

97   -­‐   97%   AFUE

Maximum   CFM

96   -­‐   96%   AFUE

         2   -­‐         800   CFM

         3   -­‐   1200   CFM

MBTU/h

         4   -­‐   1600   CFM

040   -­‐   40,000   BTU/h

100   -­‐   100,000   BTU/h

         5   -­‐   2000   CFM

060   -­‐   60,000   BTU/h

120   -­‐   120,000   BTU/h

080   -­‐   80,000   BTU/h

Summary of Contents for ACVC96

Page 1: ...ger Stainless steel secondary heat exchanger Two stage gas valve provides quiet economical heating Durable Silicon Nitride igniter Quiet two speed induced draft blower Utilizes ComfortNet communicatin...

Page 2: ...1 HASFK 2 HASFK 3 HASFK 3 HASFK High Altitude LP Gas Kit HASFK 1 HASFK 1 HASFK 2 HASFK 2 HASFK 3 LPLP03 Low LP Gas Pressure Switch LPM 08 LP Conversion Kits Accessories A C V C 96 040 3 B N A A 1 2 3...

Page 3: ...r all existing local codes For bottom return Failure to unfold flanges may reduce airflow by up to 18 This could result in performance and noise issues For servicing or cleaning a 24 front clearance i...

Page 4: ...tage Electrical Outlet Air Discharge Air Discharge Folded Flanges B 18 TOP VIEW FRONT VIEW RIGHT SIDE VIEW Air Return Air Discharge Model A B C D E ACVC960403BNA 17 14 14 14 16 ACVC960603BNA 17 14 14...

Page 5: ...ACVC960603BNA Cooling Speeds 1 8 w c ESP ACVC960603BNA Heating Speed 1 5 w c ESP Rise Range 35 65 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Low Stage CFM Rise F A Minus 10 5...

Page 6: ...ling Speeds 1 8 w c ESP ACVC961005CNA Heating Speed 1 5 w c ESP Rise Range 45 75 F Tap Adjust High Stage CFM Low Stage CFM Tap Adjust High Stage CFM Low Stage CFM Rise F A Minus 10 706 472 A Minus 10...

Page 7: ...5 1 767 1 283 60 Normal 1 399 1 000 Normal 1 860 1 350 57 Plus 5 1 469 1 050 Plus 5 1 953 1 418 55 Plus 10 1 539 1 100 Plus 10 2 046 1 485 52 D Minus 10 1 624 1 112 D Minus 10 1 726 1 249 62 Minus 5...

Page 8: ...BL O LED S DIAGNOSTIC 4 FS 1 BK 5 3 24 V THERMOSTAT CONNECTIONS NEUTRAL 1 3 2 LINE FUSE 4 2 3 A 24 V NO 2 1 SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0 7 AMPS LIMIT CONTROL AUXILIARY AUTO RESET PK W...

Reviews: