Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven and discharge capacitor
before servicing, unless testing requires it.
RS2220002 Rev. 0
20
Illustration
Component
Test
Results
4
COM
230
208
5
6
Transformer
Discharge Capacitor
Remove all wires from terminals.
Measure resistance from:
230 to COM
208 to COM
230 to Ground
208 to Ground
Terminal 5 to 6
Terminal 4 to Ground
Less than 1
Ω
Less than 1
Ω
Infinite
Infinite
Less than 1
Ω
Approximately 70
Ω
7
8
2
4
3
5
Interlock switch
Door Closed
2
4
7
3
5
8
Primary
Secondary
Monitor
Disconnect wires to switch.
With door open measure resistance from:
Terminal 2 to 3
Terminal 4 to 5
Terminal 7 to 8
With door closed measure resistance from:
Terminal 2 to 3
Terminal 4 to 5
Terminal 7 to 8
Infinite
Infinite
Indicates continuity
Indicates continuity
Indicates continuity
Infinite
A
B
Convection blower
motor
Remove wires from motor.
Measure resistance across
terminals A and B.
Approximately 20
Ω
Heating element
assembly
Disconnect wires from terminals.
Measure resistance across heating
element.
Front element
1200 W ......................
Rear element
1500 W ......................
Indicates continuity
ACE208
ACE230
35
Ω
43
Ω
29
Ω
35
Ω
Resistance thermal
device (RTD)
Temperature
32
°
F
350
°
F
Resistance
1000
Ω
1654
Ω
Lamp receptacle
Test continuity of receptacle terminals.
Indicates continuity with bulb
screwed in.