AM9S80/AC9S80
AC9S80 Dimensions
Model
A
B
Non-Combustible
Floor Base
AC9S800403A*
14”
12½”
SBT14
AC9S800603A*
14”
12½”
SBT14
AC9S800804B*
17½”
16”
SBT17
AC9S800805C*
21”
19½”
SBT17
AC9S801005C*
21”
19½”
SBT21
Notes
•
Line voltage wiring can enter through the right or left side of furnace.
Low-voltage wiring can enter through the right or left side of furnace.
•
Conversion kits for high-altitude (4500+ ft) natural gas operation are avail
-
able. Contact your Goodman distributor or dealer for details.
A
B
High-Voltage
Electrical
Low-Voltage
Electrical
Gas Inlet
19 ⅝”
28”
11 ⅜”
18 ⅜”
33 ⅜”
Minimum Clearances to Combustible Materials
Sides
Rear
Front¹
Vent²
Top
SW
B
1”
0”
3”
6”
1”
1”
¹ 24” clearance for serviceability recommended.
² Single Wall Vent (SW) to be used only as a connector. Refer to the latest editions of the National Fuel Gas
Code NFPA 54/ ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1 and
CAN/CSA B142.2 (in Canada).
Note: GMES80 approved for line contact in the horizontal position.