background image

SS-

AM9S80/AC9S80

www.amana-hac.com

13

AM9S80 Heating Airflow Data

HEATING AIFLOW

MODEL

THER-

MOSTAT 

CALL

TAP #

EXTERNAL STATIC PRESSURE, (INCHES WATER COLUMN)

0.1

0.2

0.3

0.4

0.5

CFM

RISE

CFM

RISE

CFM

RISE

CFM

RISE

CFM

AM9S80

0403A*

 W/W1

F01^^

658

N/A

585

N/A

545

N/A

495

N/A

444

F02^

749

40

697

42

652

45

607

49

554

F03

925

32

881

34

840

35

800

37

760

F04

882

34

841

35

800

37

760

39

719

AM9S80

0603A*

W/W1

F01^^

659

N/A

599

N/A

542

N/A

490

N/A

437

F02^

1268

35

1221

36

1188

37

1154

38

1122

F03

1087

41

1044

43

1008

44

973

46

938

F04

1118

40

1070

42

1033

43

997

45

963

AM9S80

0603B*

 W/W1

F01^^

720

N/A

660

N/A

614

N/A

542

N/A

468

F02^

1289

34

1260

35

1232

36

1194

37

1161

F03

1125

40

1089

41

1052

42

1013

44

973

F04

1252

36

1198

37

1153

39

1110

40

1069

AM9S80

0604B*

W/W1

F01^^

764

N/A

695

N/A

630

N/A

559

N/A

485

F02^

1287

35

1235

36

1191

37

1147

39

1104

F03

1339

33

1301

34

1258

35

1217

37

1174

F04

1396

32

1346

33

1298

34

1257

35

1217

AM9S80

0803B*

 W/W1

F01^^

710

N/A

646

N/A

580

N/A

515

N/A

432

F02^

1298

46

1255

47

1216

49

1178

50

1140

F03

1209

49

1166

51

1124

53

1083

55

1045

F04

1138

52

1091

54

1045

57

1001

59

959

AM9S80

0804B*

W/W1

F01^^

841

N/A

657

N/A

595

N/A

522

N/A

439

F02^

1141

52

1089

54

1045

57

1001

59

958

F03

1311

45

1267

47

1226

48

1189

50

1150

F04

1395

42

1347

44

1309

45

1270

47

1233

AM9S80

0804C*

W/W1

F01^^

831

N/A

750

N/A

671

N/A

588

N/A

501

F02^

1214

49

1158

51

1103

54

1045

57

989

F03

1303

45

1249

47

1191

50

1136

52

1081

F04

1426

42

1375

43

1324

45

1277

46

1229

AM9S80

0805C*

W/W1

F01^^

837

N/A

752

N/A

671

N/A

576

N/A

501

F02^

1316

45

1270

47

1218

49

1166

51

1114

F03

1353

44

1323

45

1286

46

1235

48

1183

F04

1587

37

1544

38

1506

39

1459

41

1416

AM9S80

1005C*

W/W1

F01^^

802

N/A

724

N/A

637

N/A

551

N/A

468

F02^

1405

53

1356

55

1308

57

1262

59

1210

F03

1574

47

1531

48

1484

50

1440

51

1392

F04

1619

46

1575

47

1526

49

1489

50

1446

AM9S80

1205D*

W/W1

F01^^

851

N/A

774

N/A

692

N/A

615

N/A

535

F02^

1677

53

1629

55

1583

56

1540

58

1498

F03

1537

58

1489

60

1444

62

1404

63

1365

F04^^

1416

N/A

1365

N/A

1315

N/A

1267

N/A

1220

Note:

 ^ 

DEFAULT SPEED

           ^^NOT RECOMMENDED FOR HEATING

Summary of Contents for AC9S80

Page 1: ...ment District SCAQMD on or after October 1 2019 AHRI Certified ETL Listed Installation AM9S80 upflow horizontal left or right AC9S80 downflow horizontal left or right Convenient left or right connection for gas and electrical service Heavy gauge steel cabinet with durable baked enamel finish Foil faced insulated heat exchanger Contents Nomenclature 2 Product Specifications 3 Dimensions 5 Airflow D...

Page 2: ...iguration NOx M Upflow Horizontal N 40 NG J NOx C Downflow Horizontal X 40 NG J NOx U 14NG J NOx Motor Cabinet Width 9 Nine Speed ECM A 14 C 21 B 17 D 24 Gas Valve Maximum CFM S Single Stage 3 1200 CFM 4 1600 CFM C Two Stage 5 2000 CFM AFUE MBTU h 80 80 AFUE 92 92 AFUE 030 30 000 BTU h 080 80 000 BTU hz 96 96 AFUE 97 97 AFUE 040 40 000 BTU h 100 100 000 BTU h 060 60 000 BTU h 120 120 000 BTU h ...

Page 3: ...45 8 7 12 45 12 45 12 45 12 45 15 3 Max Overcurrent Device amps 15 15 15 15 15 15 15 15 15 20 Ship Weight lbs 86 90 100 108 116 120 132 132 132 132 DOE AFUE based upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canad...

Page 4: ... upon Isolated Combustion System ICS Vent and combustion air diameters may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z223 1 in the USA and the Canada National Standard of Canada CAN CSA B149 1 and CAN CSA B142 2 in Canada Minimum Circuit Ampacity 1 25 x Circulator Blower Amps ID Blower amps Wire size should be determined in accor dance ...

Page 5: ...2 in Canada Note AMES80 approved for line contact in the horizontal position Model A B Model A B AM9S800403A 14 12 AM9S800804B 17 16 AM9S800603A 14 12 AM9S800804C 21 19 AM9S800603B 17 16 AM9S800805C 21 19 AM9S800604B 17 16 AM9S801005C 21 19 AM9S800803B 17 16 AM9S801205D 24 23 Notes Line voltage wiring can enter through the right or left side of furnace Low voltage wiring can enter through the righ...

Page 6: ...500 ft natural gas operation are avail able Contact your Goodman distributor or dealer for details A B High Voltage Electrical Low Voltage Electrical Gas Inlet 19 28 11 18 33 Minimum Clearances to Combustible Materials Sides Rear Front Vent Top SW B 1 0 3 6 1 1 24 clearance for serviceability recommended Single Wall Vent SW to be used only as a connector Refer to the latest editions of the Nationa...

Page 7: ...354 1332 1310 1288 AM9S80 0603B Y Y1 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 13...

Page 8: ... 1733 1695 1655 1618 1576 AM9S80 0805C Y Y1 F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055...

Page 9: ... 1354 1332 1310 1288 AM9S80 0603B Y2 F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 13...

Page 10: ... 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2003 1973 1946 1907 1890 AM9S80 1005C Y2 F01 802 724 637 ...

Page 11: ...1332 1310 1288 AM9S80 0603B G F01 720 660 614 542 468 413 359 313 F02 1289 1260 1232 1194 1161 1125 1087 1073 F03 1125 1089 1052 1013 973 947 909 863 F04 1252 1198 1153 1110 1069 1028 990 953 F05 922 872 830 786 736 683 616 565 F06 1146 1113 1076 1039 1002 969 933 891 F07 1370 1345 1317 1286 1260 1224 1187 1168 F08 1413 1386 1360 1330 1302 1270 1242 1211 F09 1544 1500 1459 1419 1387 1349 1317 1286...

Page 12: ...3 1695 1655 1618 1576 AM9S80 0805C G F01 837 752 671 576 501 426 361 315 F02 1316 1270 1218 1166 1114 1061 1000 962 F03 1353 1323 1286 1235 1183 1131 1085 1040 F04 1587 1544 1506 1459 1416 1372 1323 1281 F05 1731 1673 1632 1587 1546 1506 1463 1421 F06 1794 1744 1709 1671 1632 1591 1555 1513 F07 1861 1805 1761 1720 1681 1642 1603 1565 F08 1910 1873 1839 1798 1761 1723 1686 1648 F09 2110 2055 2035 2...

Page 13: ...0803B W W1 F01 710 N A 646 N A 580 N A 515 N A 432 F02 1298 46 1255 47 1216 49 1178 50 1140 F03 1209 49 1166 51 1124 53 1083 55 1045 F04 1138 52 1091 54 1045 57 1001 59 959 AM9S80 0804B W W1 F01 841 N A 657 N A 595 N A 522 N A 439 F02 1141 52 1089 54 1045 57 1001 59 958 F03 1311 45 1267 47 1226 48 1189 50 1150 F04 1395 42 1347 44 1309 45 1270 47 1233 AM9S80 0804C W W1 F01 831 N A 750 N A 671 N A 5...

Page 14: ...S80 0804B Y Y1 F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 139...

Page 15: ...1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 AC9S80 0805C Y2 F01 1022 813 674 585 511 431 334 282 ...

Page 16: ...0804B G F01 760 697 636 569 481 402 349 300 F02 1286 1238 1196 1157 1117 1077 1036 998 F03 1393 1348 1308 1270 1230 1196 1158 1123 F04 1459 1414 1371 1336 1297 1264 1229 1193 F05 1753 1713 1677 1642 1611 1576 1549 1518 F06 1309 1261 1218 1182 1142 1103 1064 1025 F07 1580 1534 1495 1459 1429 1390 1356 1324 F08 1523 1483 1438 1403 1370 1336 1299 1266 F09 1643 1599 1562 1525 1491 1462 1431 1394 AC9S8...

Page 17: ...49 876 F03 932 48 887 50 844 53 806 55 767 F04 897 N A 851 N A 808 N A 764 N A 725 AC9S80 0804B W W1 F01 760 N A 697 N A 636 N A 569 N A 481 F02 1286 46 1238 48 1196 50 1157 51 1117 F03 1393 43 1348 44 1308 45 1270 47 1230 F04 1459 41 1414 42 1371 43 1336 44 1297 AC9S80 0805C W W1 F01 1022 N A 813 N A 674 N A 585 N A 511 F02 1453 41 1407 42 1332 45 1259 47 1190 F03 1176 N A 1105 N A 1020 N A 935 N...

Page 18: ... BTU HR x 1000 BTU OUTPUT vs TEMPERATURE RISE CHART TEMPERATURE RISE 600 CFM 700 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 CFM FORMULAS BTU OUTPUT CFM x 1 08 x RISE RISE BTU OUTPUT 1 08 CFM 800 Temperature Rise Formulas BTU h Output CFRM x 1 08 x Rise Rise BTU H Output CFM CFM x 1 08 BTU h Output Vs Temperature Rise Chart Output BTU h x 1 000 ...

Page 19: ...MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105v C USE COPPER CONDUCTORS ONLY 4 UNIT MUST BE PERMANENTLY GROUNDED AND CONFORM TO N E C AND LOCAL CODES 5 TO RECALL THE LAST 6 FAULTS MOST RECENT TO LEAST RECENT DEPRESS SWITCH FOR MORE THAN 2 SECONDS WHILE IN STANDBY NO THERMOSTAT INPUTS COLOR CODES PK PINK BR BROWN WH WHITE BL BLUE GY GRAY RD RED YL YELLOW OR ORANGE PU PURPLE GN GREEN BK BLACK ...

Page 20: ...1 Downflow Sub Base 21 AFE18 60A Fossil Fuel Dual Fuel Kit HANG20 High Altitude Natu ral Gas Kit LPLP03 Low LP Gas Pressure Switch LPT 03 LP Conversion Kits Minimum Filter Sizes Model AM9S80 0403A AM9S80 0603A AM9S80 0604B AM9S80 0804B AM9S80 0805C AM9S80 81005C AM9S80 1205D Filter Size in 1 16 x 25 Side or 1 14 x 24 Bottom 1 16 x 25 Side or Bottom 1 16 x 25 Side or Bottom 2 16 x 25 Side or 1 20 x...

Reviews: