30
30
O
F
F
O
F
F
8 7
4 3 2 1
O
F
F
O
N
8 7
4 3 2 1
O
N
O
F
F
8 7
4 3 2 1
O
N
O
N
8 7
4 3 2 1
Cooling
Speed
Tap A
Cooling
Speed
Tap B
Cooling
Speed
Tap C
Cooling
Speed
Tap D
*
Cooling Speed Taps
(
*
indicates factory setting)
O
F
F
O
F
F
8 7
4 3 2 1
O
F
F
O
N
8 7
4 3 2 1
O
N
O
F
F
8 7
4 3 2 1
O
N
O
N
8 7
4 3 2 1
Heating
Speed
Tap A
Heating
Speed
Tap B
Heating
Speed
Tap C
Heating
Speed
Tap D
Heating Speed Taps
(
*
indicates factory setting)
*
O
F
F
O
F
F
8 7
4 3 2 1
O
F
F
O
N
8 7
4 3 2 1
O
N
O
F
F
8 7
4 3 2 1
Normal
+ (Plus)
Adjust
- (Minus)
Adjust
Adjust Taps
(
*
indicates factory setting)
*
Startup Procedure and Adjustment
Adjust Blower Heat Off Delay
The integrated control module provides a selectable heat
off delay function. The heat off delay period may be set to
60, 90, 120, 180 seconds using the DIP switches or jumper
provided on the control module. The delay is factory
shipped at 90 seconds but may be changed to suit the
installation requirements and/or homeowner preference.
Refer to the following figures for switch positions and
corresponding delay times.
Heat Off
Delay
60 Seconds
ON
ON
1
2
3
Heat Off
Delay
90 Seconds
Heat Off
Delay
120 Seconds
Heat Off
Delay
180 Seconds
ON
OFF
1
2
3
ON
1
2
3
1
2
3
OFF
OFF
Heat Off Delay
(* indicates factory setting)
*
OFF
Heat Off Delay Switches