Function
Range
Description
R.INP
continued
NONE
,
P.HLd
d.HLd
Hi
,
Lo
,
HiLo
,
SP.Ac,
No.Ac,
CAL.S
,
duLL
or
A.cIr
Hi
- peak memory. The peak value stored in memory will be displayed if the
remote input pins are short circuited, if the short circuit is momentary then the
display will return to normal measurement after 20 seconds. If the short circuit
is held for 1 to 2 seconds or the power is removed from the instrument then the
memory will be reset. Note if the operation is changed it is necessary to reset
the memory e.g. if changed from
Hi
to
Lo
.
Lo
- valley memory. The minimum value stored in memory will be displayed.
Otherwise operates in the same manner as the
Hi
function. Note if the
operation is changed it is necessary to reset the memory e.g. if changed from
Hi
to
Lo
.
HiLo
- toggle between
Hi
and
Lo
displays. This function allows the remote
input to be used to toggle between peak and valley memory displays. The first
operation of the remote input will cause the peak memory value to be
displayed, the next operation will give a valley memory display.
P Hi
or
P Lo
will flash before each display to give an indication of display type.
Page 19 of 27
PM4RT8MAN-1.4-0
SPFN
ChnI
R.INP
set to
HiLo
(See
P.HLd
for further description)
Operates as above
Hi
and
Lo
but will toggle between high and low
readings each time remote input is activated.
SPFN
ChnI
R.INP
set to
Lo
(See
P.HLd
for further description)
SCAN
Shows whichever channel is or has been the lowest
HIGH
Shows whichever channel is or has been the lowest
Lo
Shows whichever channel is or has been the lowest then only
changes if this channel value decreases
AUGE
Shows the lowest average of all channels
dIFF
Shows the minimum difference between any channels
dIF1
Shows the minimum difference from channel 1
ch1
Shows channel 1 valley value
ch2
to
ch 8
Shows selected channel number valley value
SPFN
ChnI
R.INP
set to
Hi
(See
P.HLd
for further description)
SCAN
Shows whichever channel is or has been the highest
HIGH
Shows whichever channel is or has been the highest
Lo
Shows whichever channel is or has been the lowest then only
changes if this channel value increases
AUGE
Shows the highest average of all channels
dIFF
Shows the maximum difference between any channels
dIF1
Shows the maximum difference from channel 1
ch1
Shows channel 1 peak value
ch2
to
ch 8
Shows selected channel number peak value