MM-315B
5. Measurement
5-3
(3) Checking Measurement Setting
Measurement setting can be checked as follows.
Press the
4#0)'
button.
The following display appears:
L o 0
0
1
Above, the Low range and Impulse No. 0 are shown, and the First Cycle is 1.
The above display will be shown when the
+/275'
01
or
(+456
%;%
button is
pushed. In addition, when the
*\
*\
,
#%
&%
, or
%;%
5'%
button is pushed,
the setting of each can be checked. To change these settings, follow the
procedures specified in “Chapter 4 (4)”. Item buttons are only for checking
measurement schedules.
To measure the weld current, press the
%744
&')
button to show the initial
display.
RANGE IMPULSE NO. FIRST CYC.
RANGE
FIRST CYCLE ---
First cycle to be
measured.
1-99 cycles
IMPULSE NO.---
Number of
impulses to be
measured. Shows
all impulses when
set to 0.
Lo: 9.99-kA range
Hi: 49.9-kA range