16
—
MO5
Display date and time, velocity, signal strength, signal quality and working
status
M06
Display the wave shape of the receiving signal
M07
Display the battery terminal voltage and its estimated lasting time
M08
Display the all the detailed working status, signal strength, signal quality
M09
Display today's total flow, velocity, signal strength, signal quality and working
status
M10
Window for entering the outer perimeter of the pipe
Mll
Window for entering the outer diameter of the pipe
0 to 6000mm is the allowed range of the value.
M12
Window for entering pipe wall thickness
M13
Window for entering the inner diameter of the pipe
M14
Window for selecting pipe material
Standard pipe materials (that the user need not know the speed ) include:
(0) carbon steel
(1) stainless steel (2) cast iron
(3) ductile iron
(4) copper
(5) PVC
(6) aluminum
(7) asbestos
(8) fiberglass
M15
Window for entering the pipe material speed only for non-standard pipe
materials
M16
Window for selecting the liner material, select none for pipes without any
liner
Standard liner materials that the user need not know the speed include:
(1) Tar Epoxy
(2) Rubber
(3) Mortar
(4) Polypropylene
(5) Polystryol
(6)Polystyrene
(7) Polyester
(8) Polyethylene
(9) Ebonite
(10) Teflon
m17
Window for entering the liner material speed only for non-standard liner
materials
M18
Window for entering the liner thickness, if there is a liner
M19
Window for entering the ABS thickness of the inside wall of the pipe
M20
Window for selecting fluid type
For standard liquids that the user need not know the liquid speed include:
(0) Water
(1) Sea Water
(2) Kerosene
(3) Gasoline
(4) Fuel oil
(5) Crude Oil
(6) Propane at -45C
(7) Butane at OC
(8)Other liquids
(9) Diesel Oil
(10)Caster Oil
(11)Peanut Oil
(12) #90 Gasoline (13) #93 Gasoline (14) Alcohol
(15) Hot water at 125C
M21
Window for entering the fluid sonic velocity only for non-standard liquids
M22
Window for entering the viscosity of the non-standard liquids
M23
Window for selecting the proper transducers
There are 14 different types of transducers for selection.
If the user-type-transducers are used, 4 user type wedge parameters, which
will be prompted by the software, should be entered following.
If the 7r type transducers are used, 37r type transducers and pipe parameters
should be entered following.
www.automat.com.ar
Dr. R. Bielsa 175 (ex Morlote) C1427AZA Buenos Aires, Argentina. Tel.: (54111) 4555-0055 / Fax: (5411) 4555-0044
INSTRU Q-FP 201
Handheld Ultrasonic Flowmeter
Summary of Contents for Instru Q-FP 201