Operating interval of pressure in water 
supply network 0,5–6,0 Atm. (50–620 kPa). 
Recommended pressure interval in water 
supply network 2,0–5,0 Atm (206–515 kPa). 
Difference of cold and hot water pressure 
may come up to ± 10%. In case of deviation 
of water supply system pressure parameters 

to the specified values installation of devices 
for pressure increase / reduction is required.

Water temperature hot water supply network 

is ≤80 

°

С. Recommended temperature of 

water in cold water supply network is 20 

°

С, 

in hot water supply network 60 

°

С.

To avoid mechanical (abrasive) particles 
penetration inside the product it is 

compulsorily required to install filters of 

100–300 mc.

mIxer InstallatIon

1. Disconnect hot and cold water supply. 
Screw in eccentric connectors (2) into 
water supply pipes outlets having sealed 
the thread part preliminary with sealer. Find 
position for eccentric connectors for them 
to coincide and be adjusted to the mixer 
connecting position (1), herewith mixer 
position should be horizontal.

attention!

 Before mixer installation check 

correctness of connections in water supply 
network: hot water connection should be 
taken out from the left side and cold water 
connection should be taken out from the 
left side of the product housing. During 
mixer installation with gas water heater it is 
necessary to know the parameters of water 
output pressure of the heater. In case of 
variation of pressure between cold and hot 
water more than 1 Atm. (103 kPa) there is a 
possibility of noise in the thermostat.

attention! 

The manufacturer reserves the 

right of making changes into mixer design 

without preliminary notification.

2. Switch on hot and cold water supply for 
short period of time. Make sure that there 
are no mechanical particles and afterwards 
disconnect water supply (do not forget to 
provide safe water discharge into sewerage 
system).

temperature adjustment:

As depending on pressure and temperature 
of water supply system actual temperature 

value fixed by safety button may deviate 
from preset 38 

°

С, after mixer installation its 

adjustment is required. For that:

The hot water

connector

The cold water

connector

2

1

3. Install decorative plates (4) onto the 

eccentric connectors (2), place filtering 

elements (3) inside mixer housing (1) and 
by means of tools with soft cover plates (to 
avoid damage of mixer decorative cover), 
connect mixer housing.

2

4

3

1

4. Switch on water supply system. During 
mixer closed position check leakproofness of 

all connections. If required arrange additional 

tightening and sealing of connections 
(having closed water supply preliminary).
5. Connect shower kit.

1

2

3

5

4

6

1. remove protective cap (5), 

2. unscrew fitting bolt (4) remove handle 
(3), decorative indicator ring (2) and fixing 

ring (1)

3. switch on water flow by means of flow 

adjustment handle 
4. by turning thermal cartridge stock (6) to 

the required side (temperature increase/
decrease), find position when water 
temperature at the outlet comprises 38С 

(use the thermometer (not included into the 
delivery set)). 

5. switch on water flow

6. make assembly (item.2) in reverse order.

mIxer operatIon

There is a safety button on thermostat handle 
(right) that prevents water temperature 

increase above 38 

°

С. For water temperature 

increase at the mixer outlet push the button 
and keep turning thermostat handle to 
increase water temperature.

maIntenance recommendatIons

Risk of breaking of mixer cartridge may be 

significantly reduced by means of installation 
of filters 100-300 mk to the mixer pipes that 

prevent penetration of foreign particles (rust, 
sand, etc.) to the mixer. 
To avoid lime spots at the mixer housing 
the mixer is recommended to be regularly 
cleaned. Mixer cleaning should be carried 
out by soap solution with the following rinse 
with water and removing moisture by dry 
soft cloth.

The remainings of liquid soap, shower gel 

may also cause damages of decorative 
cover. In case of their penetration onto 
the mixer housing it should be thoroughly 
cleaned with clean water
To avoid damages of product surface it 

is forbidden to use abrasive для ухода 

solutions and pastes.

To avoid changes color of decorative cover 
it is forbidden to use chemicals for cleaning 
that contain aggressive chemical substances 
of acids, alkali, ammonium chloride and 
other components containing chlorine.

Periodical cleaning of filtering elements 

located at the inlet nozzles of mixer is 
recommended (at least once a year). For 
this purpose:
– switch off cold and hot water supply 
system
– by means of the tool with soft cover plates 
(to avoid damage of decorative cover of 
mixer nuts) disconnect mixer housing from 
eccentric connectors

– remove filtering elements, clean them and 

install again.
– install mixer housing in accordance with  
item 3–4 of Installation instructions.

Summary of Contents for joy F8540000

Page 1: ...joy...

Page 2: ...2 3 F8540000 F8550000 F8540000 F8550000 Instruction on installation operation and maintenance of mixer Mixer for shower with thermostat EN...

Page 3: ...tools with soft cover plates to avoid damage of mixer decorative cover connect mixer housing 2 4 3 1 4 Switch on water supply system During mixer closed position check leakproofness of all connections...

Page 4: ...Sie Kalt und Warmwasserzulauf f r eine kurze Zeit Stellen Sie sicher dass es im Wasser keine Fremdstoffe gibt dann schlie en Sie den Wasserzulauf vergessen Sie nicht eine sichere Wasserausleitung ins...

Page 5: ...eduziert werden indem Filter 100 bis 300 an die Wasserversorgungsr hre vor der Mischbatterie installert werden um das Eindringen von Fremdstoffen Rost Sand usw zu verhindern Zur Vermeidung der Kalkabl...

Page 6: ...10 11 The hot water connector The cold water connector 2 1 F8540000 F8550000 RU 0 5 6 0 50 620 1 2 1 1 103 2 2 4 3 1 4 5 3 2 4 3 1 2 0 5 0 206 515 10 80 20 60 100 300...

Page 7: ...12 13 38 1 2 3 5 4 6 1 5 2 4 3 2 1 3 4 6 38 5 6 2 38 100 300 1 3 4 F8540000 F8550000 UA 0 5 6 0 50 620 2 0 5 0 206 515 10...

Page 8: ...14 15 The hot water connector The cold water connector 2 1 1 2 1 1 103 2 2 4 3 1 4 5 3 2 4 3 1 80 20 60 100 300 38 1 2 3 5 4 6 1 5 2 4 3 2 3 4 6 38 5 6 2 38 100 300 1 3 4...

Page 9: ...Uwaga Producent zastrzega sobie prawo na wprowadzenie zmian do konstrukcji baterii bez wst pnego powiadomienia 2 W cz na kr tko zimn i ciep wod Upewnij si e w wodzie brak domieszek mechanicznych nast...

Page 10: ...eri na rury wodoci gowe filtry 100 300 mk zapobiegaj ce dostaniu si wewn trz baterii cz stek obcych rdza piasek itd eby zapobiec pojawieniu si na korpusie baterii plam osad w wapiennych bateri zaleca...

Page 11: ...20 21 1 2 3 5 4 6 The hot water connector The cold water connector 2 1 1 2 1 103 2 3 2 4 2 4 3 1 4 5 3 1 80 20 60 100 300 38 1 5 2 4 3 2 1 3 4 6 38 5 6 38 100 300...

Page 12: ...22 3 4...

Page 13: ...WWW AMPM WORLD COM AM PM AG Torstrasse 177 D 10115 Berlin...

Reviews: