Supervisor 3500 Installation Instructions
Page 24
For assistance: [email protected] +1 (909) 591-8431 PUD3673R1-1
Ethernet Communication (Optional)
1. Locate the CPU board on the secured side of the master/
center cabinet.
2. Connect the Ethernet cable to the Ethernet port
[Figure 23].
It is assumed that Ethernet cabling has been run to the
turnstile via conduit and pulled through the conduit opening in
Step 6 of the Anchoring the Turnstile section.
NOTE
Fig. 23
CPU Board
Post-Installation Functions Check
Alvarado turnstiles are thoroughly inspected and tested for proper performance prior to being shipped. Perform the following
function checks to verify the turnstiles have been installed properly and are fully operational. If any problems are encountered
during the functions check, refer to the Troubleshooting section on Page 30.
Before beginning the Post-Installation Functions Check, please read the following brief descriptions of the three SU3500 passage
modes. More information on SU3500 passage modes can be found in the
SU3500 User Guide
.
(Flashing)
Passage Mode
Description
User Status
Display
Open / Closed
Status Light
Controlled Passage
The barrier wings are closed, securing the
lane. Upon receipt of an authorization signal
from an access control system the barrier
wings retract to the open position, allowing
a single passage in the authorized direction.
The barrier wings will close after the user
has passed through the turnstile or the entry
access time (6 second default) has expired.
This is the default passage mode the
SU3500s are set to before leaving the
factory.
Free Passage
An access control authorization signal is
not required for a user to pass through the
turnstile. Barrier wings are closed until a user
enters the turnstile at which time the barrier
wings automatically open. The barrier wings
will close after the user has passed through
the turnstile or the entry access time (6
second default) has expired.
No Passage
No passage is allowed. The barrier wings are
closed and remain closed. Valid electronic
credentials are ignored and passage is not
allowed. The barrier wings will still open in
the exit direction if a fire alarm or life safety
input is received.
Passage Modes
Ethernet
Port