INSTALLATION AND OPERATION MANUAL | CUL11 CONTROL UNIT
6
6
ELECTRIC MODULE
Element
Element
Description
Description
hL6
LED
indicating the operation of valve connected to
VAL2
output. Lights up when the
valve is not connected to
VAL2
output or voltage is supplied to the valve
hL7
LED
always lights up,
VAL3
output is not used for
CUL11
unit
J1
Connector for power supply connection (
fig.
3)
J2
Connectors for on-off switch 1 connection (
fig.
1,
fig.
3).
CAUTION!
The switch is designed to turn on and turn off the voltage supplied
to the unit. Do not turn off during operation, wait until the end of the
leveller finishes its working cycle
J6
J3
Connector for protective earthing (
PE
) connection
J4
Connector for light lamp connection 230 V / max. 100 W (
fig.
4).
The lamp lights when the unit has performed any first action (control button is
pressed, door position sensor is activated) and goes out when the power is turned
off. If faults in the platform operation are detected, the lamp no longer lights
(section 7 ‘Faults and recommendations on their elimination’)
J5
Connector for connection of the electric motor of hydraulic unit (
fig.
5) and
STOP
safety
sensor (
NC
).
CAUTION!
While opening the 24 V at J5 connector, control voltage of
24 V DC turns off and control unit does not operate. For control unit
operation, OUT + 24 V and IN + 24 V contacts should be closed (
NC
)
J8
Connector for connection of hydraulic unit valves (
fig.
6) and door position sensor (
fig.
8).
If the sensor is triggered, the electric motor of hydraulic unit turns off and the dock
leveller starts lowering
J9
Connector for connection of the jumper to select an output type of door position sensor:
PNP
or
NPN
(terminal output)
J10
Connector for connection of control buttons
2
and
3
,
LED
4
(
fig.
1,
fig.
7)
J12
The jumper for setting the overcurrent protection in the electric motor of hydraulic
unit. In the case of overcurrent or fault ( section 7 ‘Faults and recommendations on their
elimination’), the dock leveller movement completely stops (
STOP
).
CAUTION!
If the jumper is not set, the protection will be turned off
J13
Connector for connection of the jumper to select a contact type of door position sensor:
NO
(normally open) or
NC
(normally closed).
CAUTION!
If the door position sensor is not connected, the jumper should be
connected to
NO
contact
Y
ATTENTION!
The position of the jumper set in J12 and J13 connectors is saved when the
on-off switch 1 (
fig.
1) is switched from ‘
0
’ position (‘
Off
’ position) to ‘
I
’ position (‘
On
’ position)
and maintained during the control unit operation. If the jumper position in J12 and J13
connectors is required to be changed, power off the unit, set the jumper in the appropriate
position and power on the unit.