INSTALLATION AND OPERATION MANUAL | CUL11 CONTROL UNIT

6

6

ELECTRIC MODULE

Element

Element

Description

Description

hL6

LED

 indicating the operation of valve connected to 

VAL2

 output. Lights up when the 

valve is not connected to 

VAL2

 output or voltage is supplied to the valve

hL7

LED

 always lights up, 

VAL3

 output is not used for 

CUL11

 unit

J1

Connector for power supply connection (

fig. 

3)

J2

Connectors for on-off switch 1 connection (

fig. 

1, 

fig. 

3).

CAUTION! 

The switch is designed to turn on and turn off the voltage supplied 

to the unit. Do not turn off during operation, wait until the end of the 

leveller finishes its working cycle

J6

J3

Connector for protective earthing (

PE

) connection

J4

Connector for light lamp connection 230 V /  max. 100 W (

fig. 

4).

The lamp lights when the unit has performed any first action (control button is 

pressed, door position sensor is activated) and goes out when the power is turned 

off. If faults in the platform operation are detected, the lamp no longer lights 

(section 7 ‘Faults and recommendations on their elimination’)

J5

Connector for connection of the electric motor of hydraulic unit (

fig. 

5) and 

STOP

 safety 

sensor (

NC

).

CAUTION! 

While opening the  24 V at J5 connector, control voltage of 

24 V DC turns off and control unit does not operate. For control unit 

operation, OUT + 24 V and IN + 24 V contacts should be closed (

NC

)

J8

Connector for connection of hydraulic unit valves (

fig. 

6) and door position sensor (

fig. 

8). 

If the sensor is triggered, the electric motor of hydraulic unit turns off and the dock 

leveller starts lowering

J9

Connector for connection of the jumper to select an output type of door position sensor: 

PNP

 or 

NPN

 (terminal output)

J10

Connector for connection of control buttons 

2

 and 

3

LED

 

4

 (

fig. 

1, 

fig. 

7)

J12

The jumper for setting the overcurrent protection in the electric motor of hydraulic 

unit. In the case of overcurrent or fault ( section 7 ‘Faults and recommendations on their 

elimination’), the dock leveller movement completely stops (

STOP

). 

CAUTION! 

If the jumper is not set, the protection will be turned off

J13

Connector for connection of the jumper to select a contact type of door position sensor: 

NO

 (normally open) or 

NC

 (normally closed).

CAUTION! 

If the door position sensor is not connected, the jumper should be 

connected to 

NO

 contact

 

Y

ATTENTION! 

The position of the jumper set in J12 and J13 connectors is saved when the 

on-off switch 1 (

fig.

 1) is switched from ‘

0

’ position (‘

Off

’ position) to ‘

I

’ position (‘

On

’ position) 

and maintained during the control unit operation. If the jumper position in J12 and J13 

connectors is required to be changed, power off the unit, set the jumper in the appropriate 

position and power on the unit.

Summary of Contents for CUL11

Page 1: ...CONNECTION AND OPERATIONAL MANUAL Control unit CUL11 English 2020 www alutech group com ...

Page 2: ......

Page 3: ...LC reserves the right to change this manual without giving prior notice to customers buyers 2020 ALUTECH Door Systems CONTENT 1 General information and safety measures 3 2 Product description 4 3 Technical specifications 5 4 Electric module 5 5 Operation test and commissioning 8 6 Operation 9 7 Faults and recommendations on their elimination 10 8 Storage transportation and disposal 11 9 Warranty l...

Page 4: ......

Page 5: ...th this require ment can lead to product damage cause its malfunction fire and other hazardous situations When installing and operating there should be no foreign objects or liquids inside the product otherwise disconnect the product from mains supply and contact the service department Op erating the product in this state is unsafe The control unit is to be installed with cable glands downward to ...

Page 6: ... should be considered as an example as the place of installation can differ The task of the installer is to make the most appropriate decision The installer is responsible for work on the entire system In his work he should observe the cur rent regulations and standards e g DIN 1986 EN 12050 EN 1398 He is also responsible for main tenance of technical documentation of the entire system that is sup...

Page 7: ...ected fig 2 is located inside the control unit List of module elements Element Element Description Description FU1 T10А500V fuses CAUTION Use quartz sand filled fuses FU2 FU3 FU4 T2А500V fuse CAUTION Use quartz sand filled fuse FU5 T3 15А250V fuses FU6 FU7 HL1 LED indicating the operation of control buttons 2 and 3 fig 1 Lights up when the control button is pressed HL2 LED indicating the electric ...

Page 8: ...ff and control unit does not operate For control unit operation OUT 24 V and IN 24 V contacts should be closed NC J8 Connector for connection of hydraulic unit valves fig 6 and door position sensor fig 8 If the sensor is triggered the electric motor of hydraulic unit turns off and the dock leveller starts lowering J9 Connector for connection of the jumper to select an output type of door position ...

Page 9: ...L2 L1 PE PE J3 BU GY BK BN 1 3 5 2 4 6 YE GN Figure 2 Electronic module J3 J1 J2 HPT OUT N L3 L2 L1 PE PE HPT IN J6 3 400V J4 N LL LAMP FU7 FU6 FU5 3 T3 15A250V FU3 FU1 FU2 3 T10A500V 24V KEY4 LED 24V 24V KEY2 24V KEY3 KEY1 J10 VAL2 VAL1 24V GND GND GND VAL3 DAT J8 HL7 HL6 HL5 HL4 2 6A 3 2A 3 8A 4 4A 5A 5 6A 6 2A 6 8A 7 4A 8A 8 6A 9 2A J12 J5 W V U MOTOR IN OUT 24V LED J13 HL1 HL2 HL3 NC NO PNP NP...

Page 10: ...VAL3 DAT J8 V1 V2 24V KEY4 LED 24V 24V KEY2 24V KEY3 KEY1 LED NO NO RD BU J10 VAL2 VAL1 24 GND GND GND VAL3 DAT J8 PNP NC BN BK BU PNP NPN J9 NO NC J13 VAL2 VAL1 24 GND GND GND VAL3 DAT J8 NC PNP NPN J9 NO NC J13 VAL2 VAL1 24 GND GND GND VAL3 DAT NC PNP NPN J9 NO NC J13 A B C Figure 6 Valves connection Figure 7 Connection of control buttons and LED fig 1 J4 N LL LAMP 230V max100W J5 J3 W V U PE PE...

Page 11: ...as performed any first action control button is pressed door position sensor is activated and switches off when the power is turned off If the lamp does not light up then it is not connected or has failed If the lamp stops lighting during platform operation the fault is detected section 7 Faults and recommendations on their elimination 6 After successful completion of trial cycles the leveller sho...

Page 12: ...position in order to return the leveller to the initial position press and hold control button 2 fig 1 until the leveller lifts and the lip returns into the initial position retracts back release button and after 2 seconds the leveller automatically lowers into the initial position switch the on off switch 1 fig 1 to 0 position OFF position The scheduled maintenance of the control unit should be p...

Page 13: ...f the door position sensor is connected check whether the door is open Make sure that the sensor is connected and operational check the state change of sensor LED LED goes dim or lights up when the sensor is triggered Check the setting of jumpers in J9 and J13 connectors When pressing or button HL1 LED does not light up the dock leveller does not move Control buttons are not connected or failed Ma...

Page 14: ...er or from the date of manufacture if the date of delivery is unknown 3 Manufacturing faults that occur during the warranty period are eliminated by the service department that performs warranty maintenance Note parts replaced under the warranty become the property of the service department that performed the product repair 4 Warranty on the product is not valid in the following cases violation of...

Page 15: ...le for the installation signature print name Consumer Customer has verified the completion agreed and accepted warranty conditions and terms and has no claims against the product appearance The product is installed and ad justed in accordance with the established requirements and qualified for operation Consumer has been provided with information on existing hazards and risks as well as rules on o...

Page 16: ...ble for the repair signature _________________________________________________ print name Repair contractor information Repair operations list Date of repair Signature of the person L S responsible for the repair signature _________________________________________________ print name Repair contractor information Repair operations list Date of repair Signature of the person L S responsible for the ...

Page 17: ...INSTALLATION AND OPERATION MANUAL CUL11 CONTROL UNIT 15 15 SPECIAL NOTES ...

Page 18: ......

Page 19: ......

Page 20: ...Арт R7090139 04 2019 10 Selitskogo str 220075 Minsk Republic of Belarus Tel 375 17 330 11 00 Fax 375 17 330 11 01 www alutech group com ...

Reviews: