БЛОК УПРАВЛЕНИЯ CUID-400N
|
БЛОК УПРАВЛІННЯ CUID-400N
|
CONTROL UNIT CUID-400N
45
ELECTRONIC MODULE
Table
3. List of module elements
Element
Designation
А1
Inbuilt radio control receiver module
Learn
Remote controllers programming button
F
Drive operation mode setup button
(enter / exit setup mode; selection of the settings parameter; saving the selected settings value)
+
Selection button to increase the value of the parameter
−
Selection button to decrease the value of the parameter
CL
Settings reset button
FU1 … FU3
High-voltage fuses (10 A)
ATTENTION!
Use fuses filled with quartz sand!
FU4
Low-voltage fuse (0.8 A)
HL1, HL2
Display (display indication during the drive operation is presented in
table
5)
X1
Network connection socket
Х2
Connection socket for the electric motor of the drive
Х3
Lamps connection socket
X6
Remote control antenna connection socket
X9
Connection socket for the drive final positions switches
X10
Connection socket for the control buttons and indicators (LEDs) module, located on the
control unit housing cover
X11
Connection socket for the control devices, safety devices, additional devices (accessories)
power supply
Table
4. List of module LEDs
LED
Indication designation
Illuminates
Does not
illuminate
OP.L
Open final position switch (input ‘
OP.L
’)
was
not activated
was activated
CL.L
Closed final position switch (input ‘
CL.L
’)
was
not activated
was activated
PH1
Closing safety device (input ‘
PH1
’)
was
not activated
was activated
S
Safety device—
STOP
(input ‘
S
’)
was
not activated
was activated
CL
Close and stop command (input ‘
CL’
)
is given
is not given
OP
Command to open, stop, or close (input ‘
OP
’)
is given
is not given
SB
Movement stop command (block button ‘
STOP
’)
is given
is not given
LR
Remote control commands (remote control
AT-4
)
are given
are not given
Y
The state of LEDs, when the door is in the intermediate position and there are no com-
mands, is shown in bold.