БЛОК УПРАВЛЕНИЯ CUID-400N
|
БЛОК УПРАВЛІННЯ CUID-400N
|
CONTROL UNIT CUID-400N
54
OPERATION
•
set up correctly and test the activation of the drive final positions switches. It is
recommended to use the manual mode in the settings (section ‘6. Adjustment’, setting
‘
’) when setting the final positions. Run several full door opening / closing cycles.
When the door is in the opening final position, the control module display shows ‘
’,
and in the final closing position—‘
’.
•
set the drive operation time in the settings (section ‘6. Adjustment’, setting ‘
’).
The operation time should be sufficient to fully open and close the door (during setup
increase the time by ~ 3 seconds).
•
check the activation of every control device (buttons, switches), connected to the
control unit. Make sure the control devices work correctly and the display indications
correspond to the activated control device (
table
5).
•
check the activation of every safety device (photocells, safety margin sensor, movement
stop sensor /
STOP
, lamps), connected to the control unit. Make sure the safety devices
work correctly and the display indications correspond to the activated sensors (
table
5).
•
fasten a permanent safety sticker next to the door in a visible place, containing an
instruction with the following meaning: ‘Attention! Automatic drive. Do not stand close
to the door because of the possibility of unexpected activation’.
•
pass the completed (filled in) ‘Assembly and operation manual’ to the user (owner).
•
instruct the owner about the existing hazards and risks, and inform about safe
operation rules. Inform the owner that any person (operator), operating the equipment,
should be informed about the safety rules and the existing hazards and risks.
9.
OPERATION
Y
The product shall not be used by children or persons with limited physical, sensory or
mental abilities, as well as persons with insufficient experience and knowledge. Do not
let children play with control elements. Remote controls shall be stored in areas, unreach-
able by children.
Do not touch moving door or moving parts.
Before starting movement of the door make sure, that no people, animals, vehicles or objects
are in the danger area of the door. Monitor door movement. Passage of people and vehicles
through the moving door is prohibited.
Check the operation of safety devices every month.
Scheduled maintenance of the control unit should be performed within the maintenance of the
whole system in strict compliance with the existing regulatory documents. Perform scheduled
maintenance at least once every six months:
•
check the control unit elements (cables, buttons, electronic components etc.), paying
attention to the corrosion of the components.
•
clean the external surfaces of the control unit. Clean with the help of a soft moist cloth.
The use of the following for cleaning is forbidden: water jets, high pressure cleaners,
acids and alkali.
•
check the correct operation of the connected electric drive, control and safety devices.
10. TROUBLESHOOTING
Y
In case of a failure, which cannot be repaired based on the information, provided in this
manual, consult the service department. Information about the service department can
be obtained from your supplier (vendor, installation company).