Operation
Events are reported
to both the monitoring receiver and the interactive server. All events use
Contact ID reporting codes.
Events reported by default
• Alarms
• Alarm cancels
• Openings
• Closings
• System Low Battery
• System Low Battery Restoral
• AC Power Fail (delayed by some panels)
• AC Power Restoral (delayed by some panels)
Honeywell Vista panels can enable additional event reporting by using system programming.
Remote control
of the system can be done through the interactive services platform.
Arming/Disarm control and status
apply only to partition 1.
Z-Wave devices
can be controlled using the interactive services platform.
Factory default button
will reset the IGM if held for 5 seconds, and if held for approximately 10
seconds will factory default the IGM.
•
LED flashes twice when the IGM is factory defaulted.
Cellular LED indicators
LED
Indication
Power
(Green)
Flashing off once every second
- Primary Mode
Flashing off once every three seconds
- Backup Mode
Cellular
(Red)
ON
- Registered with the local cellular network
CS
(Red)
ON
- Connected to central station
Blinking
- Problem detecting panel type
Platform
(Yellow)
ON
- Connected to panel and interactive server
Blinking
- Problem communicating to the panel
Cellular signal bar
LEDs indicate the quality of the cellular connection. A minimum of two signal
bar LEDs is recommended.
Number of
Signal Bar LEDs
Lit
Cellular Signal Strength
0
Bad (0 to 14)
1
Marginal (15 to 19)
2
Acceptable (20 to 24)
3
Good (25 to 30)
4
Best (30+)