Altronix Trove1R Installation Manual Download Page 4

 

- 4 - 

Trove1R Installation Guide

Installing Trove1R into Rack Tower:

Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local

codes and authorities having jurisdiction. These products are for indoor use only and must be installed within 

the protected premises.

Note: First assemble and Install Z Bracket Wire Management Accesory

(refer to Z Bracket Installation pg. 4)

1.  Remove backplane from enclosure prior to installing into rack cabinet 

  (do not discard hardware).

2.  In order to mount included UL Listed tamper switch (Altronix Model TS112 or

   equivalent) turn the enclosure upside down. Punch out the knockout in 

  designated location, on the back of the unit, from outside of the drawer 

 

(Fig. 1, pg. 4)

. Insert the tamper switch into the knockout from outside of the 

  drawer with the button facing outwards and spaded connectors inside the drawer.

  Connect tamper switch wiring to the Access Control Panel input or the 

  appropriate UL Listed reporting device. 

  To activate alarm signal open the rack drawer.

3.  Slide the rack enclosure into an open 2U location in the four post rack cabinet.

4.  Utilizing proper fasteners attach front ears to the rack rails 

(Rack drawer, pg. 20)

.

5.  Attach the rear of the adjustable slides to the rear rails of the rack cabinet with the proper fasteners.

6. Secure the rack cover 

(Fig. 2a, pg. 4)

 and rack drawer 

(Fig. 2b, pg. 4) 

to earth ground

.

7. Ensure that all internal cofigurations (voltage selection, switch settings, etc.) are completed before 

  mounting backplane back into Trove rack enclosure.

Fig. 1

Back of the drawer,

viewed from outside.

Tamper Switch

mounting location

Fig. 2

Fig. 2a

Fig. 2b