background image

 

R248220 Series 

- 3 -

9.  Green power LEDs on faceplate will illuminate when AC power is present. When an output is in a trouble 
 

condition (blown fuse or tripped PTC) the corresponding LED will not be illuminated (Fig. 1, pg. 3).

 

a.  Blown fuse (R248220, R248300220, and R248600220) - set power switch on the back of the unit to the 

 

 

OFF position (Fig. 1c, pg. 3). Remove front faceplate to access fuses. 

 

 

Replace with fuses rated @ 3.5A/250VA (R248220 and R248300220). 

 

 

Replace with fuses rated @ 5A/32VA (R248600220).

 

b.  Tripped PTC (R248CB220, R248300CB220, and R248600220) - to reset PTC, set power switch on the 

 

 

back of the unit to the OFF position. After approximately 30 secs. set power switch to the ON (RESET) 

   position 

(Fig. 1c, pg. 3).

10.  Power switch with built-in circuit breaker:
 

OFF position - Switch not illuminated. Outputs not powered.

 

RESET (ON) position - Switch illuminated. Outputs powered.

 

Circuit breaker tripped - Switch not illuminated. Power LEDs on faceplate are not illuminated. 

 

Outputs not powered. To reset circuit breaker set power switch to the ON (RESET) position (Fig. 1c, pg. 3).

Note:   Do not exceed units electrical load ratings as indicated in reference chart (pg. 2).
  
Do not place mechanical load on unit. Data racks should always be properly ventilated.
 

 

Unit is designed optimally for normal data room office installations.  

CAUTION: 

Equipment to be installed / serviced by authorized / trained personnel only. 

     

Shut branch circuit power before installing / servicing equipment.

WARNING:   To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. 
     

This installation should be made by qualified service personnel and should conform to 

     

the National Electrical Code and all local codes.

P

N

N

P

Illuminated 

Power Disconnect 

Circuit Breaker

with manual reset

Strain Relief

Line Cord

Removable

Terminal

Block

 PTC1

Used 

on PTC 

Models

AC Power

LEDs

AC Power

LEDs

XFMR

XFMR

Green Wire

Earth GND

S      P       N                    S      P     N

24VAC Output

 (Factory Set)             28VAC Output

28VAC (Black)

24VAC (Yellow)

COM (Brown)

28VAC (Black)

24VAC (Yellow)

COM (Brown)

Fig. 1

Fig. 1a

Fig. 1b

Fig. 1c

Fig. 1d