Overview:

Altronix R248220 Series Rack Mount CCTV Power Supplies provide 24VAC or 28VAC distributed via eight (8) 
fuse or PTC protected outputs for powering CCTV cameras, heaters, and other video accessories.

Eight (8) Output Rack Mount Configuration Reference Chart:

Altronix 
Model Number

Total Output 

Current (Power)

Output Voltage 

(VAC)

Number of 

Outputs

PTC 

Protected 

Outputs

(auto-

resettable)

Fuse 

Protected

Outputs

Individual 

Output 

Current (max 

per output, 

not to exceed 

total output

current)

220VAC 

50/60Hz

Input Current

R248220

4A (100VA)

24

8

P

3.5A

0.9A

3.5A (100VA)

28

R248CB220

4A (100VA)

24

8

P

2.5A

0.9A

3.5A (100VA)

28

R248300220

14A (350VA)

24

8

P

3.5A

2.7A

12.5A (350VA)

28

R248300CB220

14A (350VA)

24

8

P

2.5A

2.7A

12.5A (350VA)

28

R248600220

25A (600VA)

24

8

P

5A

3A

20A (600VA)

28

R248600CB220

25A (600VA)

24

8

P

2.5A

3A

20A (600VA)

28

Specifications:

Installation Instructions:

1.  The unit is factory set for 24VAC operation. 
 

For 28VAC operation adjust unit prior to mounting and applying power as follows: 

 

a.  Open bottom of the unit by removing six (6) screws (Rack Mechanical Drawing & Dimensions, pg. 4).

 

b.  Change the wire position so that the black wire [28V] is connected to the terminal marked [P] and 

 

 

the yellow wire [24V] is connected to the terminal marked [S] (Fig. 1, pg. 3).

 

c.  After securing all wires for proper voltage place bottom panel back on the unit and fasten with the six 

 

 

(6) screws.

2.  Mount unit in the desired rack location (Space unit at least 3” from any video monitors).
3.  Set power switch on the back of the unit to the OFF position (Fig. 1c, pg. 3).
4.  Plug power cord into grounded 220VAC, 50/60 Hz receptacle (Fig. 1b, pg. 3).
5.  Set power switch on the back of unit to the ON (RESET) position and measure output voltage before 
 

connecting devices (Fig. 1c, pg. 3). This helps avoiding potential damage. 

 

All terminals with common suffix (P) “1P, 2P...” are the same polarity.

6.  Set power switch on the back of the unit to the OFF position (Fig. 1c, pg. 3).
7.  Connect devices to the removable terminal blocks marked [1P & 1N] through [8P & 8N] (Fig. 1a, pg. 3).
 

When wiring is completed on terminal blocks they can be locked down by tightening screw flanges.

8.  Upon completion of the wiring, set power switch on the back of the unit to the ON (RESET) position 
 

(Fig. 1c, pg. 3).

Agency Listings:

•  CE European Conformity

Output:

•  24VAC or 28VAC outputs.
•  Surge suppression.
•  Filtered and electronically regulated output.
•  Short circuit and thermal overload protection.

Visual Indicators:

•  Individual power LED indicators.
•  Illuminated power disconnect circuit breaker 
  with manual reset.

Features:

•  Unit maintains camera synchronization.
•  Ease of installation saves time and 
  eliminates costly labor.
•  Removable terminal blocks with 
  locking screw flanges.
•  Spare fuses provided.

Rack Dimensions 

(H x W x D)

:

•  2U rack mount chassis for use in 
  standard EIA 19” rack.
  3.26” x 19.125” x 8.5” (83mm x 486mm x 216mm)