background image

 

- 12 - 

MaximalFEV Expandable Power Systems

eFlow Power Supply/Chargers can be

Controlled and Monitored while Reporting

Power/Diagnostics from Anywhere

over the Network...

LINQ2 Mounts Inside any MaximalF Enclosure

LINQ2 - Network Communication Module

LINQ2 provides remote IP access to real-time data from eFlow power 
supply/chargers to help keep systems up and running at optimal 
levels . It facilitates fast and easy installation and set-up, minimizes 
system downtime, and eliminates unnecessary service calls, which 
helps reduce Total Cost of Ownership (TCO) - as well as creating a 
new source of Recurring Monthly Revenue (RMR) . 

LINQ2 

Features:

-  UL Listed in the U .S . and Canada .
-  Local or remote control of up to (2) two Altronix eFlow power output(s) via LAN and/or WAN .
-  Monitor real time diagnostics: DC output voltage, output current, AC & battery status/service, 
  input trigger state change, output state change and unit temperature .
-  Access control and user managment: Restrict read/write, Restrict users to specific resources
-  Two (2) integral network controlled Form “C” Relays .
-  Three (3) programmable input triggers: Control relays and power supplies via external hardware sources .
-  Email and Windows Dashboard notifications
-  Event log tracks history .
-  Secure Socket Layer (SSL) .
-  Programmable via USB or web browser - includes operating software and 6 ft . USB cable .

LINQ2 Module

Network

Connection:

Installation,

Programming

and Monitoring

L

G

N

NC

C

NO

NC

C

NO

BA

T F

AIL

AC F

AIL

AC

AC1

DC

TRIGGER EO

L

SUPER

VISE

D

disable

enable

2 hr

.

1 min

.

AC DELAY   

SHUTDOWN

O N

eFlow

Power

Supply/Charger

Summary of Contents for Maximal11FE

Page 1: ...ly 2 12VDC or 24VDC 6A Maximal33FEV Power Supply 1 12VDC or 24VDC 6A Power Supply 2 12VDC or 24VDC 6A Maximal35FEV Power Supply 1 12VDC or 24VDC 6A Power Supply 2 12VDC 10A Maximal37FEV Power Supply 1...

Page 2: ...FEV Installation Instructions pg 5 Maintenance pg 5 Power Supply Board Terminal Identification pg 6 Power Supply Board Stand by Battery Specifications pg 6 Power Supply Board LED Diagnostics pg 7 Powe...

Page 3: ...l type batteries Maximum charge current 1 54A Automatic switch over to stand by battery when AC fails Transfer to stand by battery power is instantaneous with no interruption Fire Alarm Disconnect Sup...

Page 4: ...13 2 10 03 13 2 10 1 13 2 10 05 13 2 20 19 26 4 20 19 26 4 20 28 26 4 20 2 26 4 10 0 13 2 10 03 13 2 20 28 26 4 20 2 26 4 20 19 26 4 20 19 26 4 Maximal33FEV eFlow6NBV eFlow6NBV 6A 6A 2 2 4 2 5A 250V 1...

Page 5: ...evice to the terminals marked AUX Fig 2 pg 8 Refer to page 3 for non power limited applications 6 For Access Control applications batteries are optional When batteries are not used a loss of AC will r...

Page 6: ...1A 30VDC Bat Fail NC C NO Indicates low battery condition e g connect to alarm panel Relay normally energized when DC power is present Contact rating 1A 30VDC A removed battery is reported within 5 mi...

Page 7: ...ON ON Normal operating condition ON OFF Loss of AC Stand by battery is supplying power OFF ON No DC output OFF OFF Loss of AC Discharged or no stand by battery No DC output Power Supply Board Output...

Page 8: ...positive terminal of the battery Connect black battery lead to terminal marked BAT and to the negative terminal of the battery Optional Rechargeable Stand by Battery Optional Rechargeable Stand by Ba...

Page 9: ...ns must be made employing suitable gauge CM or FPL jacketed wire or equivalent substitute Optional UL Listed battery enclosure must be mounted adjacent to the power supply via Class 1 wiring methods F...

Page 10: ...10 MaximalFEV Expandable Power Systems Notes...

Page 11: ...0 8mm 6 25 158 75mm 6 25 158 75mm 4 101 6mm 4 101 6mm 2 50 8mm 4 101 6mm 8 9 226 06mm 8 4 213 36mm 7 177 8mm 7 177 8mm 7 177 8mm 8 4 213 36mm 8 5 215 9mm 8 5 215 9mm 7 5 190 5mm 10 254mm 1 5 38 1mm 1...

Page 12: ...remote control of up to 2 two Altronix eFlow power output s via LAN and or WAN Monitor real time diagnostics DC output voltage output current AC battery status service input trigger state change outp...