LINQ8ACM(CB)
6. Output Options (program output options via LINQ software):
LINQ8ACM(CB) will provide up to eight (8) switched power outputs plus eight (8) unswitched auxiliary
power outputs.
Switched Power outputs:
Connect the negative (–) input of the device being powered to the terminal marked [COM].
• For Fail-Safe operation connect the positive (+) input of the device being powered to the terminal
marked [NC].
• For Fail-Secure operation connect the positive (+) input of the device being powered to the terminal
marked [NO].
Auxiliary Power Outputs (unswitched):
Connect positive (+) input of the device being powered to the terminal marked [C] and the negative (–)
of the device being powered to the terminal marked [COM]. Output can be used to provide power for
card readers, keypads etc.
7. Turn main power on after all devices are connected.
8
. Input Trigger Options (program trigger input options via LINQ software):
Note: If Fire Alarm disconnect is not used, connect a 10 kOhm resistor to terminals marked [GND and EOL].
Input:
Connect dry access control (NC/NO) input to terminals marked [+ INP1 –] to [+ INP8 –].
Open Collector Sink Input:
Connect the open collector sink input to the terminal marked [+ INP1 –] to [+ INP8 –].
Wet (Voltage) Input Configuration:
Carefully observing polarity, connect the voltage input trigger wires and the supplied 10K resistor to
terminals marked [+ INP1 –] to [+ INP8 –].
9.
Fire Alarm Interface Options (program fire alarm interface options via LINQ software):
A normally closed [NC], normally open [NO] input or polarity reversal input from FACP signaling circuit
will trigger selected outputs.
Normally Open Input:
Wire your FACP relay and 10K resistor in parallel on terminals marked [GND] and [EOL].
Normally Closed Input:
Wire your FACP relay and 10K resistor in series on terminals marked [GND] and [EOL].
10.
FACP Dry NC output:
Connect desired device to be triggered by the unit’s dry contact output to the terminals marked [NC] and [C].
When [EOL JMP] is kept intact, the output is of 0 Ohm resistance in a normal condition.
When [EOL JMP] is clipped, a 10k resistance will be passed to next device when in a normal condition.
Fig. 2 - LINQ8ACM
COM
-
+PWR2
+PWR1
+ PWR1 - + PWR2
-
COM
-
F- R- GND GND
C
F+ R+ EOL RST NC FACP
+ PS1 - + BAT - + PS2 - + BAT
-
BAT 1 FUSE
BAT 2 FUSE
NO C NC COM NO C NC COM
NO C NC COM NO C NC COM
NO C NC COM NO C NC COM
NO C NC COM NO C NC COM
+PWR2
+PWR1
EN<-->DIS
PWR2<-->PWR1
PWR2<-->PWR1
PWR2<-->PWR1
PWR2<-->PWR1
PWR2<-->PWR1
PWR2<-->PWR1
PWR2<-->PWR1
PWR2<-->PWR1
OUT1
OUT7
OUT2
OUT3
OUT4
OUT5
OUT6
OUT8
NC C NO
BAT
AC
Tamper
NC C NO
+ INP1 -
+ INP2 -
+ INP3 -
+ INP4 -
+ INP5 -
+ INP6 -
+ INP7 -
+ INP8 -
AC BA
T
FACP Beat Out1 Out2 Out3 Out4 Out5 Out6 Out7 Out8
OFF
PWR2
PWR1
A
Y
B
F
E
X
V
E
G
H
J
I
K
L
M
N
O
C
U
T
D
P
Y
Q
R
S
W
Z