- 4 -
eBridge4SK
3. Open a browser on the computer and enter “192.168.168.168” into the address bar. A dialog box Authentication Required will appear requesting both user
name and password enter the default values here. Click on the button labeled
Log In.
4. The status page of the eBridge4SPT will appear. This page displays the real time status and health of each device connected to the eBridge4SPT.
Network Setup:
Click on the tab labeled
Network Settings. This will open the Network Setting screen. In this screen the MAC Address of the eBridge4SPT module will be found
along with the programming fields for the Network Settings, Trap Receiver Settings, SNMP Port Settings and Email Settings.
Network Settings: In the IP Address Method field select the method that the IP Address for the eBridge4SPT will be obtained “Static” or “DHCP”
then follow the appropriate steps.
STATIC (Fig. 2a, pg. 4):
1.
IP Address: Enter the IP address assigned to the eBridge4SPT by the network
administrator.
2.
Subnet Mask: Enter the Subnet of the network.
3.
Gateway: Enter the TCP/IP gateway of the network access point (router)
being used.
Note: Gateway configuration is required to properly receive emails
from the device.
4.
HTTP Port: Enter the HTTP port number assigned to the eBridge4SPT
module by the network administrator to allow remote access and monitoring.
The default inbound port setting is 80. HTTP is not encrypted and unsecure.
Even though HTTP can be used for remote access it is recommended
primarily for use with LAN connections.
5.
HTTPS Port: Enter the HTTPS port number assigned to the eBridge4SPT
module by the network administrator to allow remote access and monitoring.
The default inbound port setting is 443. Being encrypted and more secure,
HTTPS is highly recommended for remote access.
6. Click the button labeled
Submit Network Settings. A dialog box will display
“New network settings will take effect after the server is rebooted”. Click
OK.
DHCP (Fig. 2a, pg. 4):
1. After selecting DHCP in the IP Address Method field click the button labeled
Submit Network Settings. A dialog box will display “New network settings will
take effect after the server is rebooted”. Click
OK. Next click on the button
labeled
Reboot Server. After rebooting the eBridge4SPT will be set in the
DHCP mode. The IP address will be assigned by the router when the
eBridge4SPT is connected to the network. It is recommended to have the
assigned IP Address reserved to ensure continued access (see the network
administrator).
2.
Subnet Mask: When operating in DHCP the router will assign the subnet mask values.
3.
Gateway: TCP/IP gateway of the network access point (router) being used will be displayed.
Fig. 2
Network Settings
eBridge4SPT
Site ID: RJ Sports Wear
Site ID: RJ Sports Wear
Network Settings:
IP Address Method:
IP Address:
Subnet Mask:
Gateway:
HTTP Port:
HTTPS Port:
Submit Network Settings
10.0.0.113
255.255.255.0
10.0.0.1
2713
443
event.report
••••••••
smtp.gmail.com
587
From:
Subject:
Username:
Password:
SMTP Server:
SMTP Server Port:
Outgoing Email 1:
Outgoing Email 2:
Outgoing Email 3:
Outgoing Email 4:
Outgoing Email 5:
STATIC
MAC Address: BC:34:00:30:00:B3
Reboot Server
Restore Factory Settings
Email Settings:
Trap Receiver Settings:
Trap Receiver IP Address 1:
Trap Receiver IP Address 2:
Trap Receiver IP Address 3:
Trap Receiver IP Address 4:
Trap Receiver IP Address 5:
10.0.0.102
10.0.0.56
62.19.75.80
45.165.245.146
50.74.175.125
Submit Trap Receiver IP Settings
SNMP Port Settings:
SNMP Port:
Trap Message Port:
161
162
Submit Port Settings
Test Email
Restore Default
Submit Email Settings
Management Interface
Events Log
v1.99.22
Security Settings
Network Settings
Setup
Status
Dashboard
Linq
Lab Linq2 “A”
Lab Linq2 “B”
Netway
Netway16M
Netway4ES
Netway8M
Netway1DWPM
FireSwitch
FireSwitch
eBridge
eBridge4SPT
eBridge200WPM
eBridge16PCRX
> eBridge16PCRX [50.74.149.196:2717] added.
> eBridge200WPM [50.74.149.196:2712] added.
> eBridge4SPT [50.74.149.196:2713] added.
> FireSwitch [ 50.74.149.196:2710 ] added.
> Netway1DWPM [ 50.74.149.196:2716 ] added.
> NetWay8M [ 50.74.149.196:2715 ] added.
> Netway4ES [ 50.74.149.196:2714 ] added.
> Netway16M [ 50.74.149.196:2707 ] added.
> Lab Linq2 “B” [ 50.74.149.196:2703 ] added.
Ethernet adapter detected.
Trap receiver Port: 162
File Setup Help
DEVICE NAVIGATION PANEL
LOG
Site ID
Trap Message
USB Network Setup
DEVICE ALERTS
WEBVIEW INTERFACE
b.
a.
c.
d.