15
Electrical safety
Use an extension cable in compliance with IEC 60245 (H 07
RN-F) having a core cross-section of at least:
−
1.5 mm
2
for cable lengths up to 25 m
−
2.5 mm
2
for cable lengths over 25 m
Long and thin connection lines result in a voltage drop. The
motor does not reach any longer its maximal power; the
function of the device is reduced.
Plugs and coupler outlets on connection cables must be
made of rubber, non-rigid PVC or other thermoplastic
material of same mechanical stability or be covered with this
material.
When installing the power supply cable observe that it does
not interfere, is not squeezed, bended and the plug
connection does not get wet.
Wind off completely the cable when using a cable drum.
Do not use the cable for purposes for which it is not meant.
Protect the cable against heat, oil and sharp edges. Do not
use the cable to pull the plug from the socket.
Check the extension cable on a regular basis and replace it
if it is damaged.
Do not use any defective connection cables.
Do not set up any provisional electrical connections.
Never bypass protective devices or deactivate them.
Only hook up the machine by means of a fault-current circuit
breaker (30 mA).
The electrical connection or repairs to electrical parts of
the machine must be carried out by a certified electrician
or one of our customer service points. Local regulations –
especially regarding protective measures – must be
observed.
Repairs to other parts of the machine must be carried out
by the manufacturer or one of his customer service points.
Use only original spare. Accidents can arise for the user
through the use of other spare parts. The manufacturer is
not liable for any damage or injury resulting from such
action.
F
F
u
u
n
n
c
c
t
t
i
i
o
o
n
n
p
p
r
r
i
i
n
n
c
c
i
i
p
p
l
l
e
e
This air dehumidifier works on the basis of the condensation
principle.
Room air is sucked through a filter and a refrigerating element
where water vapour in the air condense as water droplets.
Then, the water droplets flow into a condensation water bowl
and further into the water container while the dried cold air is
piped through the condenser of the device, heated and blown
again into the room. The temperature of the blown out air is
approx. 2-5 °C above the room temperature. This increase of
heat is caused by power introduced in the compressor and fan
and by heat which is released by the condensation of the water
vapour.
The relative humidity of air is gradually reduced thanks to
continuous recirculation of the room air through the device
resulting in a quick and gentle drying of the room.
L
Water vapours move easily and unhindered through the
air. Therefore, it is essential to “seal” the room as tight as
possible. That means doors and windows must kept
closed and entering and leaving the room should be
restricted if possible. Otherwise the drying efficiency of the
device is considerably impaired.
A
A
s
s
s
s
e
e
m
m
b
b
l
l
y
y
Assembly transport wheels
1.
Place the air dehumidifier horizontally.
2.
Turn the transport handle upwards and secure it to the
enclosure using the 2 hexagon screws M6x40 and the
washers A 6.4.
L
Do not tighten the screws too firmly.
3.
Insert the connecting pieces (4) in the legs (2/3). Insert the
legs in the transport handle and secure them to the
enclosure using the 6 hexagon screws M6x40 and the
washers A 6.4.
L
Tighten all screws.
Summary of Contents for LDH 500
Page 34: ...34 L L L 16...
Page 35: ...35 IEC 60245 H 07 RN F 1 5 25 2 5 25 PVC 30 mA 2 5 C L 1 2 2 M6x40 A 6 4 L 3 4 2 3...
Page 36: ...36 6 M 6x40 A 6 4 L 1 5 M 6 x 30 2 15 5 3 6 7 10 cm L 230 V FI 30 mA 10 A 45 L...
Page 38: ...38 20 C 5 C L 45 E4 5 1 2 3 8 4 5 6 E4 1 2 9 3 4 12 5 L...
Page 39: ...39 L 1 2 10 40 C 1 2...
Page 40: ...40 a 5 C 32 C b 30 c 10 cm a b a b a b L L 2 E3 E4 E5 L E3 E5...