The water collecting container of the air dehumidifier is
equipped with a float switch which turns off the device when the
collecting container is full.
L
After 45 seconds, compressor and fan will automatically
stop, and an acoustic signal will sound. The
icon and
the fault code E4 will be displayed.
Another acoustic signal will sound every 5 minutes if the
water collecting container is not immediately emptied.
Removing the water collecting container
1.
Turn off the device.
2.
Open the enclosure door.
3.
Remove the container (8) and empty is immediately.
4.
Re-insert the container. Make sure that the container is
correctly positioned.
5.
Close the hinged enclosure cover.
6.
Restart the air dehumidifier. The
icon and the fault code
E4 should no longer be displayed.
Icon and fault code are further displayed? Remove the
container again and re-insert it properly.
Continuous or extended operation
In the case of a high humidity of air it is recommended to
operate the air dehumidifier in continuous mode. In
continuous mode it is not needed to empty the water
collecting container.
Proceed as follows:
1.
Remove the water collecting container from the device.
2.
Remove the stopper (9).
3.
Re-insert the collecting container in the device.
4.
Guide a suited hose (internal diameter 12.5 mm) through
the enclosure. Carefully connect the hose.
L
Pay attention to the following:
@
Make sure that the water can flow out unhindered.
@
Pipe the water preferably to a drain which is
positioned at a lower level.
@
Make sure that the hose remains in its position, is
routed with a descending gradient, is not kinked or
wound up.
T
T
r
r
a
a
n
n
s
s
p
p
o
o
r
r
t
t
Power off the device and disconnect the mains
plug before each transport.
Always transport the air dehumidifier in upright (vertical) position
to prevent compressor damages.
Hint: If you have transported the air dehumidifier in
another than upright position (horizontal or tilted),
allow the air dehumidifier to stand in upright position
for at least one hour before starting it up.
Summary of Contents for LDH 500
Page 34: ...34 L L L 16...
Page 35: ...35 IEC 60245 H 07 RN F 1 5 25 2 5 25 PVC 30 mA 2 5 C L 1 2 2 M6x40 A 6 4 L 3 4 2 3...
Page 36: ...36 6 M 6x40 A 6 4 L 1 5 M 6 x 30 2 15 5 3 6 7 10 cm L 230 V FI 30 mA 10 A 45 L...
Page 38: ...38 20 C 5 C L 45 E4 5 1 2 3 8 4 5 6 E4 1 2 9 3 4 12 5 L...
Page 39: ...39 L 1 2 10 40 C 1 2...
Page 40: ...40 a 5 C 32 C b 30 c 10 cm a b a b a b L L 2 E3 E4 E5 L E3 E5...
Page 143: ......