. 4) 03/16 • ASC SERIES CONVECTION OVENS • 7
I N S T A L L A T I O N
The oven must be installed by a qualified electrician.
This appliance must be branch circuit protected with
proper ampacities, in accordance with the wiring
diagram located in this manual or in the electrical
compartment of the oven. The oven must be properly
grounded in accordance with the National Electrical
Code and applicable local codes. Plug the unit into a
properly grounded receptacle ONLY, positioning the
unit so that the plug is easily accessible in case of an
emergency. Arcing will occur when connecting or
disconnecting the unit unless all controls are in the
OFF position.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed by
a licensed electrician in accordance with applicable
local electrical codes.
Wire size for the main incoming power to the
unit must match the minimum size listed in the
specifications applicable to the specific oven model.
For supply connections, locate the wire size posted
on the label located near the electric terminal block
behind the service panel or elsewhere listed in this
manual. Before attempting the electrical connection,
the rating plate should be checked to ensure that
the electrical characteristics of the appliance and the
electrical supply characteristics agree.
Installation of the wiring must be made in
accordance with U.L. 197 Commercial Electric
Cooking Appliance Standards, Local and/or
National Electrical Code, ANSI /NFPA 70-1990.
Service line entry is made through the rear of the
oven for connection to the terminal block. Remove
the service panel on the right side of the oven for
access to the terminal block.
The oven is wired at the factory for either single
phase or three phase service as indicated on the
original purchase order. Input voltage and phase
must match the voltage and phase of the oven.
Visually check all electrical connections.
W A R N I N G
To prevent SERIOUS INJURY,
DEATH, or PROPERTY DAMAGE:
All electrical connections must be
made by a qualified and trained
service technician in accordance
with applicable electrical codes.
This appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence
of local codes, with the current
edition of the National Electrical
Code ANSI/NFPA No. 70. In Canada,
all electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
E L E C T R I C A L C O N N E C T I O N
W A R N I N G
To prevent SERIOUS INJURY, DEATH
or PROPERTY DAMAGE:
All electrical connections must be
made by a qualified and trained
service technician in accordance with
applicable electrical codes.
CAUTION
Power source must match voltage identified
on appliance rating tag. The rating tag
provides essential technical information
required for any appliance installation,
maintenance or repairs. Do not remove,
damage or modify the rating tag.
ELECTRICAL - ASC-4E
VOLTAGE
PHASE
CYCLE
/
HZ
AWG
AMPS
kW
208
1
60
6
50.0
10.4
240
1
60
6
43.3
10.4
208
3
60
8
28.8
10.4
240
3
60
8
25.0
10.4
440-480
3
60
12
13.6
10.4
220
1
50
6
40.0
8.7
NO CORD AND PLUG
ELECTRICAL - ASC-2E
VOLTAGE
PHASE
CYCLE
/
HZ
AWG
AMPS
kW
208
1
60
10
24.0
5.0
240
1
60
10
20.8
5.0
208
3
60
12
13.8
5.0
240
3
60
12
12.0
5.0
NO CORD AND PLUG
Summary of Contents for PLATINUM Series
Page 31: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 29 ...
Page 32: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 30 ...
Page 33: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 31 2 ...
Page 34: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 32 2 2 ...
Page 35: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 33 ...
Page 36: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 34 2 2 ...
Page 37: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 35 2 ...
Page 38: ...MN 28666 Rev 4 03 16 ASC SERIES CONVECTION OVENS 36 2 2 ...