background image

#838• IN STA L L ATION / OPERATION / SERVIC E MA N UA L •

14.

Thermostat

TT-3057

Terminal

Block

BK-3019

Cord

CD-3551

208V

CD-3922

230V

CD-33824

125V

Bushing

BU-3964

Switch

SW-34351

208V & 230V

SW-34375

125V

Temperature

Gauge

GU-34198

S e r v i c e V i e w

M A N U A L C O N T R O L

- 1 0 0 0 - U P

Control Side

Summary of Contents for Halo Heat 1200-UP

Page 1: ... USA PHONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY WEBSITE www alto shaam com P R I N T E D I N U S A F o o d H o l d i n g C a b i n e t E l e c t r i c Models 1000 UP 1200 UP Manual Control INSTALLATION OPERATION MAINTENANCE 1000 UP HD 1200 UP HD ...

Page 2: ...ple using or installing the equipment model Contact the Alto Shaam service department if you have any questions concerning installation operation or maintenance NOTE All claims for warranty must include the full model number and serial number of the unit UNPACKING 1 Carefully remove the appliance from the carton or crate NOTE Do not discard the carton and other packaging material until you have in...

Page 3: ...e of a hazard that can or will cause minor personal injury property damage or a potential unsafe practice if the warning included with this symbol is ignored Used to notify personnel of installation operation or maintenance information that is important but not hazard related 1 This appliance is intended to cook hold or process foods for the purpose of human consumption No other use for this appli...

Page 4: ...f maintaining hot food at a temperature for safe consumption The unit must be installed on a level surface in a location that will permit the equipment to function for its intended purpose and allow adequate access for proper cleaning and maintenance 2 The appliance must not be installed in any area where it will be affected by steam grease dripping water high temperatures or any other severely ad...

Page 5: ... 89mm 2 RIGID CS 25674 Casters 3 1 2 89mm 2 SWIVEL W BRAKE CS 25675 Door Lock with Key LK 22567 HACCP Network Options ELECTRONIC CONTROL ONLY REFER TO SPECIFICATION 9015 FOR APPLICABLE PART NUMBERS HACCP Documentation HACCP with Kitchen Management Legs 6 152mm Flanged SET OF FOUR 5004863 Pan Grid Wire chrome plated PN 2115 PAN INSERT 18 x 26 457mm x 660mm x 25mm Probe Internal Temperature ELECTRON...

Page 6: ...k with Key LK 22567 HACCP Network Options ELECTRONIC CONTROL ONLY REFER TO SPECIFICATION 9015 FOR APPLICABLE PART NUMBERS HACCP Documentation HACCP with Kitchen Management Legs 6 152mm Flanged SET OF FOUR 5004863 Pan Grid chrome plated wire PN 2115 PAN INSERT 18 x 26 457mm x 660mm x 25mm Probe Internal Temperature ELECTRONIC CONTROL AVAILABLE Universal Angle Configuration Pan Slides Chrome Plated ...

Page 7: ...s in close vicinity an equalization bonding stud is provided An equalization bonding lead must be connected to this stud and the other appliances metal parts to provide sufficient protection against potential difference The terminal is marked with the following symbol NOTE The appliance must be connected to an electrical circuit that is protected by an external GFCI outlet USA ONLY 1 2 0 20 8 24 0...

Page 8: ...emperature 2 Set holding thermostat to 95 F 35 C 3 Pour approximately 2 quarts c 2 liters of hot water 140 180 F 60 82 C into a pan on the bottom surface of the holding compartment 4 Preheat cabinet for 45 60 minutes 5 Remove covering and place product in preheated cabinet 6 Allow dough to remain in the cabinet until it approximately doubles in size 7 Remove product from cabinet and bake according...

Page 9: ...ood should be placed into the cabinet Before loading the unit with food use a food thermometer to make certain all food products are at an internal temperature range of 140 to 160 F 60 to 71 C All food not within the proper temperature range should be heated before loading into the holding cabinet 3 Reset the thermostat to 160 F 71 C Check to make certain the cabinet door is securely closed and re...

Page 10: ...time period allowed for the initial heat to be released from the product Most Halo Heat holding equipment is provided with a thermostat control between 60 and 200 F 16 to 93 C If the unit is equipped with vents close the vents for moist holding and open the vents for crisp holding If the unit is equipped with a thermostat indicating a range of between 1 and 10 use a metal stemmed indicating thermo...

Page 11: ...removed and the area wiped as soon as possible but at the very least a minimum of once a day Always thoroughly rinse surfaces after using a cleaning agent and wipe standing water as quickly as possible after rinsing CLEANING AGENTS Use non abrasive cleaning products designed for use on stainless steel surfaces Cleaning agents must be chloride free compounds and must not contain quaternary salts Ne...

Page 12: ...acid muriatic acid on stainless steel 4 Clean control panel door vents door handles and door gaskets thoroughly since these areas harbor food debris Rinse by wiping with sponge and clean warm water Wipe dry with a clean cloth 5 Interior can be wiped with a sanitizing solution after cleaning and rinsing This solution must be approved for use on stainless steel food contact surfaces 6 To help mainta...

Page 13: ...mbly 5005606 Casing Back 1004988 Casters 5 rigid CS 24874 Casters 5 swivel w brake CS 24875 Control Panel Bezel PE 26567 Control Panel Overlay PE 26875 Door Assembly 15147 Door Gasket GS 22952 Door Handle HD 27080 Door Hinge HG 2535 Side Panels 1004985 Side Rack SR 2120 Temperature Gauge GU 34198 Thermostat Knob KN 26568 1000 UP ...

Page 14: ...1 LI 3951 Line Filter 230V only FI 33225 FI 33225 Switch Rocker 125V SW 34375 SW 34375 Switch Rocker 208V 230V SW 34351 SW 34351 Terminal Block BK 3019 BK 3019 Thermostat Manual TT 3057 TT 33432 S E R V I C E includes CB 3044 Cable Heating Element 108 feet CR 3226 Ring Connector 4 IN 3488 Insulation Corner 1 foot BU 3105 Shoulder Bushing 4 BU 3106 Cup Bushing 4 ST 2439 Stud 4 NU 2215 Hex Nut 8 SL ...

Page 15: ...A L 14 Thermostat TT 3057 Terminal Block BK 3019 Cord CD 3551 208V CD 3922 230V CD 33824 125V Bushing BU 3964 Switch SW 34351 208V 230V SW 34375 125V Temperature Gauge GU 34198 S e r v i c e V i e w M A N U A L C O N T R O L 1 0 0 0 U P Control Side ...

Page 16: ...mostat TT 33432 Terminal Block BK 3019 Cord CD 3551 208V CD 3922 230V CD 33824 125V Bushing BU 3964 Switch SW 34351 208V 230V SW 34375 125V Temperature Gauge GU 34198 Temperature Gauge GU 34198 S E R V I C E V I E W M A N U A L C O N T R O L 1 2 0 0 U P Control Side Control Side ...

Page 17: ... 838 IN STA L L ATION OPERATION SERVIC E MA N UA L 16 ...

Page 18: ... 838 IN STA L L ATION OPERATION SERVIC E MA N UA L 17 ...

Page 19: ... 838 IN STA L L ATION OPERATION SERVIC E MA N UA L 18 ...

Page 20: ... 838 IN STA L L ATION OPERATION SERVIC E MA N UA L 19 ...

Page 21: ... 838 IN STA L L ATION OPERATION SERVIC E MA N UA L 20 ...

Page 22: ... 838 IN STA L L ATION OPERATION SERVIC E MA N UA L 21 ...

Page 23: ... 15 months from the shipping date whichever occurs first THIS WARRANTY DOES NOT APPLY TO 1 Calibration 2 Replacement of light bulbs and or the replacement of display case glass due to damage of any kind 3 Equipment damage caused by accident shipping improper installation or alteration 4 Equipment used under conditions of abuse misuse carelessness or abnormal conditions including but not limited to...