An electrical wiring diagram is located behind the control
panel on the left side of the oven. This appliance must be
branch circuit protected with proper ampacities, in
accordance with the wiring diagram located in the
electrical compartment of the oven.
Wire size for the main incoming power to the unit must
match the minimum size listed in the specifications
applicable to the specific oven model. For supply
connections, locate the wire size posted on the label
located on the electrical control box cover, behind the
service panel.
Before operating the oven, check all cable connections in
the electrical connection area for tightness since
connections can loosen during transport.
NOTE: After both water and elecrical connections have
been completed, operate the oven in any cooking
mode for a period of 15 minutes and recheck the
main power connections at the terminal block to
make certain they remain tight.
G A S C O M B I T H E R M
—
I N S T A L L A T I O N M A N U A L
#MN-28676
PG
. 14
®
C O M B I T HE R M
E L E C T R I C A L & I N S TA L L AT I O N R E Q U I R E M E N T S
AVERTISSEMENT: Directives pour la prise
de courant électrique Cet appareil est muni
d'une fiche à trios branches (prise de
Courant) afin de vous proéger des chocs et
doit être branché Directemet dans un
receptacle adequate de prise do courant À
trios branches. II ne faut pas couper ou
enlever une banche De cette fiche.
MODEL
VOLTAGE
PHASE CYCLE
/
HZ
AMPS
KW
CIRCUIT
AWG
6•10esG
110-120
1
50/60
5.7
.68
20 A
2
WIRE
PLUS GROUND
6•10esG/
SK
110-120
1
50/60
9.5
1.14
20 A
AWG
12
7•14esG
110-120
1
50/60
5.7
.68
20 A
2
WIRE
PLUS GROUND
7•14esG/
SK
110-120
1
50/60
9.5
1.14
20 A
AWG
12
10•10esG
110-120
1
50/60
5.7
.68
20 A
2
WIRE
PLUS GROUND
10•10esG/
SK
110-120
1
50/60
9.5
1.14
20 A
AWG
12
10•20esG
110-120
1
50/60
7.8
.936
20 A
2
WIRE
PLUS GROUND
AWG
12
12•18esG
110-120
1
50/60
7.8
.936
20 A
2
WIRE
PLUS GROUND
AWG
12
20•20esG
110-120
1
50/60
22.0
2.64
30 A
2
WIRE
PLUS GROUND
AWG
10
OTHER VOLTAGES AVAILABLE
: Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz
380-415V:
To prevent an electrical shock hazard
between the appliance and other appliances
or metal parts in close vicinity, an
equalization-bonding stud is provided.
An equalization bonding lead must be
connected to this stud and the other
appliances / metal parts to provide
sufficient protection against potential
difference. The terminal is marked with
the following symbol.
D A N G E R
ELECTRICAL GROUNDING
INSTRUCTIONS:
This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into a
properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.