# 8 9 1 / 3   •     I N S TA L L AT I O N / O P E R AT I O N / S E RV I C E   M A N U A L •  15.

Food flavor and aroma are usually so closely related 
that it is difficult, if not impossible, to separate them.
There is also an important, inseparable relationship
between cleanliness and food flavor.  Cleanliness, top
operating efficiency, and appearance of equipment
contribute considerably to savory, appetizing foods.
Good equipment that is kept clean, works better and
lasts longer.

Most food imparts its own particular aroma and 
many foods also absorb existing odors.  Unfortunately,
during this absorption, there is no distinction between
GOOD  and BAD odors.  The majority of objectionable
flavors and odors troubling food service operations are
caused by bacteria growth.  Sourness, rancidity,
mustiness, stale or other OFF flavors are usually the
result of germ activity.

The easiest way to insure full, natural food flavor is
through comprehensive cleanliness.  This means good
control of both visible soil (dirt) and invisible soil
(germs).  A thorough approach to sanitation will
provide essential cleanliness.  It will assure an attractive
appearance of equipment, along with maximum
efficiency and utility.  More importantly, a good
sanitation program provides one of the key elements 
in the prevention of food-borne illnesses. 

A controlled holding environment for prepared foods 
is just one of the important factors involved in the
prevention of food-borne illnesses.  Temperature
monitoring and control during receiving, storage,
preparation, and the service of foods are of equal
importance.

The most accurate method of measuring safe
temperatures of both hot and cold foods is by internal
product temperature.  A quality thermometer is an
effective tool for this purpose, and should be routinely
used on all products that require holding at a specific
temperature.

A comprehensive sanitation program should focus on
the training of staff in basic sanitation procedures.  
This includes personal hygiene, proper handling of raw
foods, cooking to a safe internal product temperature,
and the routine monitoring of internal temperatures
from receiving through service.

Most food-borne illnesses can be prevented through
proper temperature control and a comprehensive
program of sanitation.  Both these factors are important
to build quality service as the foundation of customer
satisfaction.  Safe food handling practices to prevent
food-borne illness is of critical importance to the health
and safety of your customers.  HACCP, an acronym for
Hazard Analysis (at) Critical Control Points, is a quality
control program of operating procedures to assure food
integrity, quality, and safety.  Taking steps necessary to
augment food safety practices are both cost effective
and relatively simple.  

While HACCP guidelines go far

beyond the scope of this manual, additional information
is available by contacting

Center for Food Safety and Applied Nutrition 

Food and Drug Administration 

1-888-SAFEFOOD

S A N I T A T I O N

I N T E R N A L F O O D P R O D U C T T E M P E R A T U R E S

H O T   F O O D S

DANGER ZONE

40° TO 140°F

(4° TO 60°C)

CRITICAL ZONE

70° TO 120°F

(21° TO 49°C)

SAFE ZONE

140° TO 165°F

(60° TO 74°C)

C O L D   F O O D S

DANGER ZONE

ABOVE 40°F

(ABOVE 4°C)

SAFE ZONE

36°F TO 40°F

(2°C TO 4°C)

F R O Z E N   F O O D S

DANGER ZONE

ABOVE 32°F

(ABOVE 0°C)

CRITICAL ZONE

0° TO 32°F

(-18° TO 0°C)

SAFE ZONE

0°F 

OR BELOW

(-18°C 

OR BELOW

)

Summary of Contents for 10-18W

Page 1: ...in 53052 0450 USA PHONE 262 251 3800 800 558 8744 USA CANADA FAX 262 251 7067 800 329 8744 U S A ONLY WEBSITE www alto shaam com P R I N T E D I N U S A H o l d i n g C a b i n e t s E l e c t r i c M...

Page 2: ...using or installing the equipment model Contact the Alto Shaam service department if you have any questions concerning installation operation or maintenance NOTE All claims for warranty must include t...

Page 3: ...a hazard that can or will cause minor personal injury property damage or a potential unsafe practice if the warning included with this symbol is ignored Used to notify personnel of installation opera...

Page 4: ...evel 5 In order to maintain standards established by the National Sanitation Foundation floor models must be sealed at bottom by NSF approved sealant or equipped with casters or 6 152mm legs to provid...

Page 5: ...ted by an external GFCI outlet Electrical Installation ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES To avoid electrical shock th...

Page 6: ...erm Oven QC 40 Quickchiller 15639 Slide In Pan Rack Fits 10 10 Combitherm Oven QC 40 Quickchiller 15637 Slide In Pan Rack Fits 10 18 Combitherm Oven QC 40 Quickchiller 15638 Rack Track Fits inside 7 1...

Page 7: ...ack trolley 14940 rack track 15637 slide in pan rack 14582 rack track 15638 slide in pan rack 22 3 8 568mm 24 5 8 625mm 19 15 16 507mm 25 3 4 654mm 26 3 8 670mm 30 762mm 20 993 533 2mm 19 933 506 3mm...

Page 8: ...LATION Do not operate this holding cabinet without its appropriate Roll in Cart DESCRIPTION PART NO Preheat Sealing Strip 14598 Model 12 20 Roll in Pan Cart electric oven 5814 Model 12 20G Roll in Pan...

Page 9: ...INSTALLATION Do not operate this holding cabinet without its appropriate Roll in Cart DESCRIPTION PART NO Preheat Sealing Strip 14598 Model 20 20 Roll in Pan Cart electric 5815 Model 20 20G Roll in P...

Page 10: ...Slide In Pan Rack for the 10 18W and the Roll In Cart for the 12 20 and 20 20 are completely interchangeable between the Combitherm Oven and the Halo Heat Companion Holding Cabinet along with compati...

Page 11: ...ton allows the programming mode to become active L E D Display The L E D display will show the set point temperature value when programming or the warming chamber s temperature when calling for heat W...

Page 12: ...20 20 or Slide in Pan Rack on Model 10 18W LOADING THE CABINET Load the cabinet with hot food only The purpose of this unit is to maintain hot food at proper serving temperature Use a food thermomete...

Page 13: ...ods however a maximum of 1 to 2 minutes must be the only time period allowed for the initial heat to be released from the product This unit is equipped with a thermostat control between 60 and 200 F 1...

Page 14: ...e removed and the area wiped as soon as possible but at the very least a minimum of once a day Always thoroughly rinse surfaces after using a cleaning agent and wipe standing water as quickly as possi...

Page 15: ...clean cloth or air dry Leave door open until interior is completely dry Replace shelves 9 Interior can be wiped with a sanitizing solution after cleaning and rinsing This solution must be approved fo...

Page 16: ...measuring safe temperatures of both hot and cold foods is by internal product temperature A quality thermometer is an effective tool for this purpose and should be routinely used on all products that...

Page 17: ...wire shelves completely empty the holding compartment B Make certain the holding cabinet sensor located inside the holding compartment at the left side of the unit is completely clean C Suspend the t...

Page 18: ...k wires for integrity Check for proper and secure connections at the thermostat and terminal block If necessary re secure the faulty connections Energize system after the above steps have been complet...

Page 19: ...427 BLOCK MOUNTING SCREWS 2 SC 2239 SENSOR T BLOCK 1 BK 33546 20 SOLID STATE RELAY 1 RL 3736 HEAT SINK 1 HE 23421 21 THERMOSTAT 1 TT 33563 22 TRANSFORMER 208 240V 230V 1 TN 3935 23 POWER SWITCH 1 SW 3...

Page 20: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 19...

Page 21: ...OP ASSEMBLY 1 14595 4 TOP MOUNTING SCREWS 4 SC 2425 5 CASING LEFT HAND 1 13681 6 CASING RIGHT HAND 1 13680 7 CASING MOUNTING SCREWS 10 SC 2425 8 CORD 1 CD 3588 CORDSET 230V TYPE HO7 RN F 1 CD 3922 FIL...

Page 22: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 21...

Page 23: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 22...

Page 24: ...EMBLY 1 14595 4 TOP MOUNTING SCREWS 4 SC 2425 5 CASING LEFT HAND 1 13683 6 CASING RIGHT HAND 1 13682 7 CASING MOUNTING SCREWS 12 SC 2425 8 CORD 1 CD 3588 CORDSET 230V TYPE HO7 RN F 1 CD 3922 FILTER 23...

Page 25: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 24...

Page 26: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 25...

Page 27: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 26...

Page 28: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 27...

Page 29: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 28...

Page 30: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 29...

Page 31: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 30...

Page 32: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 31...

Page 33: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 32...

Page 34: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 33...

Page 35: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 34...

Page 36: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 35...

Page 37: ...891 3 INSTALLATION OPERATION SERVICE MANUAL 36...

Page 38: ...rom the shipping date whichever occurs first THIS WARRANTY DOES NOT APPLY TO 1 Calibration 2 Replacement of light bulbs and or the replacement of display case glass due to damage of any kind 3 Equipme...

Reviews: