background image

 USER’S MANUAL

SSUV40_USERS_MANUAL_REV_20200720

SS-UV40 SPECTRA SERIES UV LED

Summary of Contents for SPECTRA SS-UV40

Page 1: ...USER S MANUAL SSUV40_USERS_MANUAL_REV_20200720 SS UV40 SPECTRA SERIES UV LED ...

Page 2: ...entario sug erencia o corrección con respecto a este manual favor de dirijirlo a la oficina de Altman Lighting más cercana Der Inhalt dieses Handbuches ist nur für Informationszwecke gedacht Aenderungen sind vorbehalten Alt man Lighting uebernimmt keine Verantwortung für Fehler oder Irrtuemer die in diesem Handbuch auftreten FürBemerkungen und Verbesserungsvorschlaege oder Vorschlaege in Bezug auf...

Page 3: ...n research related to product improvement New materials production methods and design refinements are introduced into existing products without notice as a routine expression of the philosophy For this reason any current Altman Lighting product may differ in some respect from its published description but will always equal or exceed the original design specifications unless otherwise noted Our Com...

Page 4: ...er to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to the control It is recom mended that a qualified electrician perform this...

Page 5: ...ditional Resources Altman Lighting Product Warranty Altman Lighting Inc a subsidiary of Altman Stage Lighting Company Inc herein referred to as Altman war rants each new product except for spare parts or products Altman does not manufacture for a period of TWO 2 years from date of shipment to correct by repair or replacement any part defect due to faulty material or workmanship Under these same te...

Page 6: ...ust be visibly marked with the RMA number and the product must be returned shipping prepaid to the factory at 1400 East 66th Avenue Denver CO 80229 USA 1 303 500 7072 support altmanlighting com The return must be within THIRTY 30 days of receiving the RMA from Altman Altman warrants for NINETY 90 days any spare part it manufactures On spare parts or products Altman does not manufacture such as lam...

Page 7: ...Page 7 SS UV40 Installation Users Manual Table Of Contents Contents Contents Important Information 4 Product Overview 8 Installation And Setup 9 Operation 10 Cleaning And Care 15 ...

Page 8: ...s for precise control of beam direction and overall coverage The fixture is supplied with a state of the art microprocessor controlled solid state LED light engine incorporating four 365nm LEDs and an on board power supply The LED substrate is coupled to a highly efficient circuit board and convection heat sink cooling system for prolonged life of the LEDs All com ponents and electrical devices ar...

Page 9: ...e UV LED module for permanent mounting to a wall floor or ceiling Use proper length screws or bolts to mount the module in the desired location using all four mounting holes provided on the UV LED module brackets Note that the brackets can be removed and reoriented for easier access to the mounting holes Mounting brackets are also provided on the Electronics power and control box for permanent mou...

Page 10: ...made by using the three buttons on the back of the unit while power is on These include DMX Address Fixture Personalities Stand Alone Effects Local Channel Control Lock the Fixture from unwanted changes after programming Master Control Mode DMX MODE This mode is used for setting DMX address Personalities Stand Alone Effects STAND ALONE MODE This mode is used for setting the fixture to a desired in...

Page 11: ...n PERSONALITIES A total of 8 personalities are available Each personality is made up of 3 settings RESOLUTION 8 Bit 16 Bit MASTER On Off and SMOOTHING On Off These are displayed in the chart below The current active Personality is displayed for about 1 second during power up The format is Pxx where xx is replaced by the active personality 01 08 To set the desired Personality the fixture must be in...

Page 12: ...DMX channels Channel order is UV1 UV2 UV3 UV4 M 605 Personality 05 16 Bit Master OFF Smoothing OFF 8 DMX channels Channel order is UV1 Coarse UV1 Fine UV2 Coarse UV2 Fine UV3 Coarse UV4 Fine UV4 Coarse UV4 Fine 606 Personality 06 16 Bit Master OFF Smoothing ON 8 DMX channels Channel order is UV1 Coarse UV1 Fine UV2 Coarse UV2 Fine UV3 Coarse UV4 Fine UV4 Coarse UV4 Fine 607 Personality 07 16 Bit M...

Page 13: ...aster 709 slower 740 749 3 2 4 1 fade 740 faster 749 slower 780 789 1 4 2 3 A fade 780 faster 789 slower 790 799 A 3 2 4 1 fade 790 faster 799 slower UV Strobes 800 879 800 809 ALL STROBE 800 faster 809 slower 810 819 1 STROBE 810 faster 819 slower 820 829 Reserved 820 faster 829 slower 830 839 2 STROBE 830 faster 839 slower 840 849 3 STROBE 840 faster 849 slower 850 858 1 4 2 3 RAINBOW STROBE 850...

Page 14: ...Page 14 SS UV40 Installation Users Manual NOTE When entering or exiting fixed intensity mode the display will go blank Touch any button to turn on display ...

Page 15: ... vacuum to remove any dust and dirt from the lens electronics and heat sink For the lens use a soft lint free cloth dampened with water to clean the lens of dust and dirt Dry off completely with compressed air or a dry lint free cloth Do not use cleaning agents that are reactive to UV light on the lenses Doing so will risk lens cataract and void the warranty ...

Reviews: