OPERATION MENU AND OPTIONS
DMX Control
DMX Address
1 to 512
Menu Category
Control Type
Option 1
Option 2
Option 3
Factory Default
001
DMX Resolution 8 Bit
16 Bit
8 Bit
Master Channel
Off
On
Off
Smoothing
Off
On
On
DMX Loss
off
Hold Last Look
Preset (cue 1)
Off
DMX Control
-DMX Address (1-512)
-DMX Resolution (8 Bit or 16 Bit)
-Master Channel (Off or On)
-Smoothing (Off or On)
-DMX Loss (Off, Hold Last Command, Preset)
Operation Menu and Options
To address your fixture follow these steps:
1-Power the fixture and wait for the startup to complete. The screen will turn off.
2-Press ENTER and you will see “
DMX Control
” press ENTER again.
3-When the screen shows “DMXAdr 1” press ENTER again. The up and down arrows should now
be next to address 1.
(See image 2 below)
4-Press the UP or DOWN buttons to scroll to your desired DMX address.
5-Press ENTER to confirm the address.
6-Press MENU to back out of the DMX address setting.
Up and down
arrows must be
next to the num-
ber in order to
scroll to your de-
sired DMX ad-
dress.
The table below demonstrates the DMX Control Options you can choose from. By following the
same steps to address your fixture you can choose any of the following options from below.
DmxAdr
1
Menu Category
Control Type
Options
Factory Default
DMX Control
DMX Address
1 to 512
001
Dmx Resoution
8 Bit
8 Bit
16 Bit
Master Channel
Off
Off
On
Smoothing
Off
On
On
Action on DMX Loss
Off
Off
Hold Last Look
Preset (Cue 1)
The table below demonstrates the DMX Control Options you can choose from. By following the steps to ad-
dress your fixture you can choose any of the following options from below.
DMX Addressing:
1. Power the fixture and wait for the startup to complete.
(The screen will turn off.)
2. Press ENTER and you will see “DMX Control” Press EN-
TER again.
3. When the screen shows “DMXAdr 1” press ENTER
again. (See image)
4. The up and down arrows should now be next to the
number. By pressing the UP or Dwon buttons you can
now scroll to your desired DMX address.
5. Press ENTER to confirm the address.
6. Press MENU to back out of the DMX address setting.
Button Control Explanation
Button
Control / Function
MENU Move to previous menu and cancel current action
ENTER
Select and accept current action
UP
Scroll up through options and selections
DOWN
Scroll down through options and selections
DMX 512 Connections
DMX 512 Signal
XLR Pin
Common (Drain)
1
DMX 512 Minus (-)
2
DMX 512 Plus (+)
3
Note: Remaining pins on each connector are not used