INSTALLATION AND SET UP
PEGASUS 6” and 8” Fresnel
Installation
&
User’s
Manual
T-HANDLE TILT LOCK
7.5” X 7.5” COLOR
FRAME HOLDER
STEEL YOKE ASSEMBLY
POWER CONNECTION - DMX CONTROL MODE:
The PEGASUS Luminaire should be connected to either a
constant circuit or relay device when in DMX mode. Note: Altman Lighitng recommends that all Non-Dim
circuits powering solid state luminaires are routinely powered down to both conserve energy and maximize
luminare performance.
POWER CONNECTION - MAINS DIM CONTROL MODE:
When PEGAUS is set to Mains Dim Mode the lumi-
naire should be connected to a Phase cut dimmer either forward or reverse phase. Typical Phase Cut dimmers
include SCR’s (Silicon Controlled Rectifiers), IGBT’s (Insulated Gate Bipolar Transistors), and TRIAC dimmers).
The Pegaus Luminaire operates on 120 to 230 volts AC (+/- 10%, auto-ranging). Depending on supply voltage,
each luminaire can draw up to 130 Watts. The maximum through current should not exceed 20 Amps*.
IMPORTANT AC POWER CONNECTION NOTES:
a. Must be supplied by a branch either dimming or constant circuit protected by a maximum 20 Amp circuit
protector.
Doit être alimenté par un circuit de dérivation protégé par un maximum de 20 ampères circuit protecteur.
b. When using the daisy-chain connection method, ONLY connect PEGASUS Luminaires to AC Output Con-
nection of PEGASUS Luminaires. DO NOT CONNECT OTHER TYPES OF LUMINAIRES OR DEVICES!
c. Use only use approved cable types.
d. Do not overload circuits!
f. The MAXIMUM allowable number of PEGASUS Luminaires which can be 'daisychained'
CONNECTING POWER
on one power feed should not exceed ratings. DO NOT EXCEED!
Connecting Power
Units can be powered in one of two ways:
• Direct connection to a AC power source using a supplied AC input cable.
• Daisy chain connection using a interconnect AC cable.
Field wiring of PEGASUS Luminaire is straight forward. A total of 3 wires/conductors
need to be brought to the unit. The following wiring scheme is required: Please consult:
http://www.neutrik.com/en/video/powercon/powercon-20-a/nac3fca
For additional powerCON blue and grey wiring and assembly information.
Wire Color
Purpose
Brown (230V) Black (120V)
Main/(L)ine (120 to 230 VAC)
Blue (230V) White (120V)
(N)eutral
Green/Yellow (230V) Green (120V)
Ground / Earth
PAGE 7
WARNING!
The maximum allowable input current is 20 Amps (and the maximum power supply limit of 130
Watts). Do not overload circuits! Luminaires must be supplied by a branch circuit protected by a maximum 20
Amp circuit protector. Doit être alimenté par un circuit de dérivation protégé par un maximum de 20 ampères
circuit protecteur. Ne surchargez pas les circuits !