PAGE 8
PEGASUS 6” and 8” Fresnel Installation
&
User’s
Manual
WARNING! To prevent injury or death, you must have access to a main circuit breaker or other power discon-
nect device before installing any wiring. Be sure that power is disconnected by removing fuses or turning the
main circuit breaker off before installation. Installing the device with power on may expose you to dangerous
voltages and damage the device. A qualified electrician must perform this installation.
Note: The PEGASUS Luminaire is intended for installation in accordance with the National Electric Code and
local regulations. To assure full compliance with local codes and regulations, check with your local electrical
inspector before installation. The PEGASUS Luminaire is not intended for residential use or installation.
Power Feed from
Phase Cut Dimming system
(forward or reverse phase)
Power daisy chain
to next luminaire
via powerCON thru
connection. DO
NOT CONNECT
MORE THAN
FOUR (4) UNITS
TO A DIMMER.
SPECIAL NOTE:
PEGASUS must be set to MAINS CONTROL (switch on the back of the luminare) to be con-
trolled via a phase cut dimming system. Please select the dimming system dim curve for local voltage to either
115VAC or 220VAC If switching between DMX CONTROL and MAINS CONTROL. Please remove power from
Luminiare and
Wait 10 Seconds
before switching the luminaire to MAINS CONTROL.
When PEGAUS is set to Mains Dim Mode the luminaire should be connected to a Phase cut dimmer either for-
ward or reverse phase. Typical Phase Cut dimmers include: SCR’s (Silicon Controlled Rectifiers), IGBT’s (Insul-
lated Gate Bipolar Transistors), and TRIAC dimmers).
NOTE MAINS DIM CONTROL MODE: DO NOT CONNECT MORE THAN FOUR (4) PEGASUS
FRESNELS TO THE SAME DIMMER. CONNECTING MORE THAT FOUR UNITS ON THE SAME DIM-
MER WILL RESULT UNDESIRED LOW END DIMMER RESPONSES.
The Pegasus Luminaire operates on 120 to 230 volts AC (+/- 10%, auto-ranging). Depending on supply voltage,
each luminaire can draw up to 130 Watts. The maximum through current should not exceed 20 Amps*.
CONNECTING PEGASUS TO A DIMMING SYSTEM
WARNING:
DO NOT Daisy chain both MAINS DIMMABLE Luminaires with Luminaires that require CON-
STANT POWER. When Pegaus is connected to a dimming system ONLY Pegasus Luminaires should be daisy
chained together. Failing to follow these guidelines will result in unwanted dimming performance and potential
damage to the luminaires.