background image

INTERFACES

2

PRECAUTIONS / SAFETY WARNINGS

1

Please read this manual carefully before using your

VA6835FC

 Interface. Keep this manual handy for

future reference. These safety instructions are to
ensure the long life of your 

VA6835FC 

and to

prevent fire and shock hazard. Please read them
carefully and heed all warnings.

1.1 GENERAL

 Unauthorized personnel shall not open the unit

since there are high-voltage components
inside.

 Qualified Altinex service personnel, or their

authorized representatives must perform all
service.

1.2. SAFETY GUIDELINES FOR THE RACK-

MOUNTING OF THE VA6835FC

 Maximum operating ambient temperature is 35

(degrees C).

 Never restrict the airflow through the devices’

fan or vents.

 When installing equipment into a rack, distribute

the units evenly. Otherwise, hazardous
conditions may be created by an uneven weight
distribution.

 Connect the unit to a properly rated supply

circuit.

 Reliable Earthing (Grounding) of Rack-Mounted

Equipment should be maintained.

1.3 INSTALLATION

 For best results, place the 

VA6835FC

Interface on a flat, level surface in a dry area
away from dust and moisture.

 To prevent fire or shock, do not expose this

unit to rain or moisture. Do not place the

VA6835FC

 Interface in direct sunlight, near

heaters or heat radiating appliances, or near
any liquid. Exposure to direct sunlight, smoke,
or steam can harm internal components.

 Handle the 

VA6835FC

 Interface carefully.

Dropping or jarring can damage internal
components.

 Do not place heavy objects on top of the

VA6835FC

. If the 

VA6835FC

 is to be mounted

to a table or wall, use only Altinex made
mounting accessories, such as brackets
(

DA1293FC 

or

 DA1294FC

) and cables for

optimum setup.

 To turn off the main power, be sure to remove

the cord from the power outlet. The power
outlet socket should be installed as close to
the equipment as possible, and should be
easily accessible.

 Do not pull the power cord or any cable that is

attached to the 

VA6835FC

 Interface.

 If the 

VA6835FC

 Interface is not used for an

extended period, disconnect the power cord
from the power outlet.

1.4 CLEANING

 Unplug the 

VA6835FC

 power cord before

cleaning. Clean surfaces with a dry cloth.
Never use strong detergents or solvents, such
as alcohol or thinner. Do not use a wet cloth or
water to clean the unit.

1.5 FCC / CE NOTICE

 This device complies with Part 15 of the FCC

Rules. Operation is subject to the following two
conditions: (1) This device may not cause
harmful interference, and (2) this device must
accept any interference received, including
interference that may cause undesired
operation.

 This equipment has been tested and found to

comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide
reasonable protection against harmful
interference when the equipment is operated
in a commercial environment. This equipment
generates, uses, and can radiate radio
frequency energy and, if not installed and
used in accordance with the instruction
manual, may cause harmful interference to
radio communications. Operation of this
equipment in a residential area is likely to
cause harmful interference in which case the
user will be required to correct the interference
at his own expense.

Summary of Contents for VA6835FC

Page 1: ...INTERFACES MANUAL PART NUMBER 400 0062 003 PRODUCT REVISION 2 VA6835FC SYSTEM UNIVERSAL INTERFACE USER S GUIDE...

Page 2: ...d customers throughout the world This manual covers VA6835FC VGA Pack VA6835FC MAC Pack VA6835FC SUN SGI Pack VA6835FC RGB Pack VA6835FC Combo Pack VA6835FC Super Pack TABLE OF CONTENTS Page PRECAUTIO...

Page 3: ...If the VA6835FC is to be mounted to a table or wall use only Altinex made mounting accessories such as brackets DA1293FC or DA1294FC and cables for optimum setup To turn off the main power be sure to...

Page 4: ...output 1 if the input signal is RGsB The VA6835FC is a state of the art piece of equipment with an exceptional combination of compact size advanced features and very competitive pricing TECHNICAL SPE...

Page 5: ...INTERFACES 4 Horizontal Position Range 20 Cross talk 39dB 100MHz Power Internal Power Supply 90 140V 200 240V Power Consumption Table 3 VA6835FC Electrical VA6835FC DESCRIPTION 4...

Page 6: ...INTERFACES 5...

Page 7: ...ype monitor breakout cables There is no need to terminate the unused output The termination switch on the VA6835FC affects only the terminations of the computer video input The output is VGA compatibl...

Page 8: ...control will click into a locked position In this position the VA6835FC outputs the same sync types which are fed into it from the source In this setting the VA6835FC will not provide horizontal posi...

Page 9: ...s It is not necessary to terminate this output with a termination plug if a local monitor is not being used Step 5 Connect one end of a BNC cable to output one or two of the VA6835FC units Connect the...

Page 10: ...ese ID Bits will even allow the computer to recognize what type of monitor is connected in terms of its scan rate compatibility When the I D Bit switch is in the ON position the VA6835FC allows the ma...

Page 11: ...5 BNC to 5 BNC coaxial cable CB4212MR 12 ft 5 BNC to 5 BNC coaxial cable CB4225MR 25 ft 5 BNC to 5 BNC coaxial cable CB4250MR 50 feet 5 BNC to 5 BNC coaxial cable CB4275MR 75 feet 5 BNC to 5 BNC coax...

Page 12: ...c turn OFF the HV OUTPUT dip switch and connect only 4 wires RGBS to the red green blue and sync connectors 4 When and why would I use the Sync on Green dip switch although the unit does not separate...

Page 13: ...pressed or implied Altinex neither assumes nor authorizes any other person to assume for it any other liability in connection with the sale of the products This warranty shall not apply to any product...

Reviews: