background image

SWITCHERS

12

This command sets a unique ID number to each

MX2436RM 

Switcher

 

module and allows control

of multiple modules through a single RS-232
port.

In order to control multiple modules
independently with one RS-232 port, the unit ID
is used. Setting the unit ID allows a user to
send the same command to multiple modules,
but the module processes that command with
the indicated ID number only. The factory
default unit ID=1.

7.2.3 SUMMARY OF COMMANDS

      1.  [# SW n1 n2 n3 n4 n5 n6] - Video Switch
           Input

      2.  [# SW n1 n2 n3 n4 n5 n6] - Audio Switch
           Input

      3.  [#RF] - Factory Reset

      4.  [#RO]  - Operation Reset

      5.  [# SA n] - Audio Breakaway

      6.  [#Bn] - Beep ON/OFF

      7.  [OASn] - Auto Switch

      8.  [0I#] - Change Identification Number

      9.  [#CA n1 n2 ] - Audio Gain Control Save
           Settings

    10.  [#CA n1 n2 ] - Equalization Save Settings

    11.  [#VR] - Firmware Version

ACCESSORIES

8

Model No.

Description
TABLE MOUNT HARDWARE

TM1276

Table Mount bracket for 2U ½ Rack-
Wide

RACK MOUNTING ACCESSORIES

DA1298RM

Rack mount shelf for two units side by
side

DA1292RM

Rack mount ears for single unit.

HIGH RESOLUTION 5 BNC to 5 BNC
COAXIAL CABLE

CB4200MR

Bulk Cable 5 coaxes (500ft minimum)

CB4203MR

3 feet, 5 BNC to 5 BNC coaxial cable

CB4206MR

6 feet, 5 BNC to 5 BNC coaxial cable

CB4212MR

12 feet, 5 BNC to 5 BNC coaxial cable

CB4225MR

25 feet, 5 BNC to 5 BNC coaxial cable

CB4250MR

50 feet, 5 BNC to 5 BNC coaxial cable

CB4275MR

75 feet, 5 BNC to 5 BNC coaxial cable

CB42100MR

100 feet, 5 BNC to 5 BNC coaxial cable

CB42150MR

150 feet, 5 BNC to 5 BNC coaxial cable

SUPER HIGH RESOLUTION 5 BNC to
5 BNC COAX

CB4400MR

Bulk Cable 5 coaxes (500ft minimum)

CB4406MR

6 feet, 5 BNC to 5 BNC coaxial cable

CB4412MR

12 feet, 5 BNC to 5 BNC coaxial cable

CB4425MR

25 feet, 5 BNC to 5 BNC coaxial cable

CB4450MR

50 feet, 5 BNC to 5 BNC coaxial cable

CB4475MR

75 feet, 5 BNC to 5 BNC coaxial cable

CB44100MR

100 feet, 5 BNC to 5 BNC coaxial cable

CB44150MR

150 feet, 5 BNC to 5 BNC coaxial cable

POWER CABLES

PC5301US

Power cable for US

PC5302US

Power cable for U.K.

PC5303US

Power cable for Australia

PC5304US

Power cable for Germany

Summary of Contents for MX2436RM

Page 1: ...SWITCHERS MANUAL PART NUMBER 400 0129 001 PRODUCT REVISION 0 MX2436RM 6 IN 1 OUT COMPOSITE VIDEO AUDIO SWITCHER USER S GUIDE...

Page 2: ...DE 5 AUDIO BREAK AWAY MODE 5 EQUALIZATION MODE 5 AUTO SWITCH MODE 5 AUTO ROTATION MODE 5 AUDIO VOLUME CONTROL 5 VERTICAL INTERVAL SWITCHING 5 BEEP ON OFF MODE 5 RESET MODE 5 FACTORY RESET MODE 5 APPLI...

Page 3: ...of the MX2436RM If the MX2436RM is to be mounted to a table or wall use only ALTINEX made mounting accessories such as rack mount shelf DA1298RM or rack mount ears DA1292FC and cables for optimum setu...

Page 4: ...units can be rack mounted side by side TECHNICAL SPECIFICATION 3 FEATURES DESCRIPTION Audio Video GENERAL Inputs 6 8 Input Connector Six 5 conductor terminal blocks Eight BNC Female Outputs 1 1 Outpu...

Page 5: ...SWITCHERS 4 DESCRIPTION OF MX2436RM 4...

Page 6: ...puts connected to the video output will be selected alternately Audio inputs will simultaneously connect to the audio output along with video inputs if the user did not previously select AUDIO BREAK A...

Page 7: ...SWITCHERS 6 APPLICATION DIAGRAM 5...

Page 8: ...pressed and released a beeper will sound once If a button is pressed and held a beeper will sound several times 2 Default video and audio inputs are selected simultaneously by pressing and releasing...

Page 9: ...e primary communication standard used by control systems and computers In fact the MX2436RM offers more features using RS 232 than are currently available from the front panel of the unit The MX2436RM...

Page 10: ...fter processing a valid command an OK string will be returned if requested by the feedback command 7 2 2 PROGRAMMING COMMANDS NOTE These programming commands are used for programming the switcher they...

Page 11: ...ated by the factory default setting Note that previously stored settings will be lost Example Sending the 8RF command resets the Switcher module with ID number eight to the factory settings 4 RO Opera...

Page 12: ...er eight In addition by default the switcher still has ID number zero 9 CA n1 n2 Audio Gain Control Save Settings Switch number default is 0 no from 1 to 9 n1 Audio input number no from 0 to 6 n2 Audi...

Page 13: ...DA1298RM Rack mount shelf for two units side by side DA1292RM Rack mount ears for single unit HIGH RESOLUTION 5 BNC to 5 BNC COAXIAL CABLE CB4200MR Bulk Cable 5 coaxes 500ft minimum CB4203MR 3 feet 5...

Page 14: ...ignal formats 5 Can the MX2436RM Switcher be used outside of the United States Yes the MX2436RM uses a universal internal power supply enabling it to be used throughout the world Please make sure to u...

Page 15: ...ducts that you have ordered and that this product fulfills your need In the unlikely event that an ALTINEX product needs to be returned please follow the policies below Altinex will accept product ret...

Reviews: